FOUR NOZZLES VACUUM FILLING MACHINE
CHAPTER 3 – CLEANING AND MAINTENANCE
For replacing the nozzles, loosen the nut and take away the screw (fig. 9). Unfasten the nozzle with its arms from the rod
Unhook the spring. For installing another nozzle follow the procedure backwards.
No maintenance is required, except for cleaning and sanitizing before and after use.
In order to clean equipment, after rising, isolate the equipment by sectioning power supply.
The recovery tank can be washed with water alone or, in case of edible oil bottling, with dishwashing liquid.
When handling different products, kits supplied by Tenco s.r.l. (Oil kit, Jar kit, Tomato kit, ecc.) are recommended.
To replace the nozzles, rotate the “T” handle by half turn and remove the “U” pin (fig. 9). Open the two
plastic elements
of the lever and disconnect the entire assembly fron the rod. Then disengage the spring. To install others nozzles, follow
the above instructions in the opposite way.
CHAPTER 4 - DIAGNOSTICS
4.1
POSSIBLE TROUBLES WHILE ENOLMASTER IS RUNNING
In case of malfunctioning and/or breakdown/failure, set the main switch OFF and disconnect the machine to the supply.
Any operation on the parts inside the case shall be performed by authorised and specifically trained personnel.
Warning: any operation on equipment shall be performed after releasing any remaining pressure and disconnecting from
mains (see chap. 2- point 9).
If things go wrong, check the table below. If none of the solutions listed gives a positive result, get in touch with our
authorized retailer.