FOUR NOZZLES VACUUM FILLING MACHINE 

 

 
CHAPTER 1 – GENERAL DIRECTIONS AND 
INSTRUCTIONS

 

1.1 

FOREWARD 

Before using Enolmaster, carefully read these directions for use. 
 

1.2 

DESCRIPTION OF EQUIPMENT 

Enolmaster is a professional vacuum filling machine for the filling of approx. 600 bottles/hour. 

 

1.3 

USE 

This equipment is to be used with wine, oil, spirits, fruit juices, perfumes, lotions, essential oils 
 
NOTE: Products with more than 20% alcohol content could damage Enolmaster. 
Therefore, in this case, we  recommend to request the equipped equipped with pyrex recovery vessel. 
In case the machine is used with the filter, please request TANDEM PROFESSIONAL (equipped with pyrex filter holder). 
Also,  if  Enolmaster  is  employed  to  fill  sugary  liquors  or  products  like  balsamic  vinegar,  the  air  filtering  unit    must  be 
employed  to  avoid  damage  to  the  machine  vacuum  pump;  this  accessory  is  not  part  of  the  standard  supply  and,  if 
necessary, it must be ordered directly from the manufacturer. 
Tenco  srl.  shall  not  be  held  responsible  in  case  of  malfunctioning  of  Enolmaster  when  the  machine  is  operated  to  fill 
products as those described above, without using the above specified accessories. 
 

 

1.4 

TECHNICAL FEATURES 

Refer to the label on the machine. 
 

1.5 

CUSTOMER’S RESPONSIBILITY 

Installation  of  filling  machines  in  premises  complying  with  all  applicable  sanitary  regulations  and  fitted  with  certified 
electrical systems shall be responsibility of the user. 

 

1.6 

CONNECTION AND START-UP 

Place the equipment on a suitable surface. Connect the machine air treatment group to a compressor through a ø 8 mm 
flexible hose. The machine is equipped with a quick connector for ø 8 mm hose. 

 

1.7 

SAFETY INSTRUCTIONS 

Do not spill liquids into slots. 
Do not open the machine, and, if so, only after power disconnection 

 

1.8 

DIRECTIONS FOR USE 

 

1.8.1. 

Start-up: this equipment is started by acting on the relevant supply slide valve. 

1.8.2.   When the pump is working, in case the vacuum indicator is not moving, exert a small pressure on the 

recovery vessel cover and check that the vacuum regulator is completely open (turned clockwise) 

 

1.8.3. 

Stopping and emergency procedures: emergency stop is activated by sectioning the mains through the 
slide valve (OFF position) or by pressing the red emergency button. To release, turn the button until it 
returns to the normal position. 

 
IMPORTANT

: if you switch engine off while using Enolmaster, it’s absolutely necessary, before switching it on again, to 

raise knob until there is no vacuum, (fig. 7). The same operation must be performed to remove the bowl cover. 

 

 

Summary of Contents for Enolmaster

Page 1: ...1 16036 Avegno GE Tel 39 0185 79556 E mail info tenco it Web www tenco it FOUR NOZZLES VACUUM FILLING MACHINE TECHNICAL HANDBOOK PNEUMATIC T e n c o S r l Via Arbora 1 16030 Avegno GE ITALY Tel 39 018...

Page 2: ...IONS 4 1 1 FOREWARD 4 1 2 DESCRIPTION OF EQUIPMENT 4 1 3 USE 4 1 4 TECHNICAL FEATURES 4 1 5 CUSTOMER S RESPONSIBILITY 4 1 6 CONNECTION AND START UP 4 1 7 SAFETY INSTRUCTIONS 4 1 8 DIRECTIONS FOR USE 4...

Page 3: ...We Tenco s r l Unipersonale VIA ARBORA 1 16030 AVEGNO GE ITALY dichiariamo sotto la ns responsabilit che declare under our own responsibility that La riempitrice a depressione Riempitrice a depressio...

Page 4: ...ed above without using the above specified accessories 1 4 TECHNICAL FEATURES Refer to the label on the machine 1 5 CUSTOMER S RESPONSIBILITY Installation of filling machines in premises complying wit...

Page 5: ...ucked in 9 Place the bottles on the proper base and one after the other into the nozzles When the bottle is properly placed the lever should be in horizontal position fig 5 To properly adjust the leve...

Page 6: ...il info tenco it Web www tenco it FOUR NOZZLES VACUUM FILLING MACHINE KNOB GASKET FLOAT BOWL COVER B A Fig 1 Fig 2 Fig 3 END SUCTION PIPE L 2m Fig 4 Fig 5 LEVER ROD KNOB A B Fig 6 2 1 Fig 7 Fig 9 Fig...

Page 7: ...y Tenco s r l Oil kit Jar kit Tomato kit ecc are recommended To replace the nozzles rotate the T handle by half turn and remove the U pin fig 9 Open the two plastic elements of the lever and disconnec...

Page 8: ...he suction pipe is resting on the demijohn bottom 7 the bottle mouth edge is chipped 8 the rubber ring of the closing cone is broken 9 the nozzles fail to slide properly 1 check 2 close it well by pus...

Page 9: ...transport means of the Manufacturer from improper maintenance failure of electrical equipment improper use or negligence or adjustments repairs carried out by service personnel not duly authorized by...

Page 10: ...UUM FILLING MACHINE MIGNON SET INSTALLATION 1 Loosen the column knobs 2 Pull out the T rod 3 Install the miniature bottles stand 2 or 4 positions on the T rod Pull in the rod on its column Fasten the...

Page 11: ...700 0007 000 Rev 0 Pag 11 Tenco Srl Via Arbora 1 16036 Avegno GE Tel 39 0185 79556 E mail info tenco it Web www tenco it FOUR NOZZLES VACUUM FILLING MACHINE ENOLMASTER BASE...

Page 12: ...l info tenco it Web www tenco it FOUR NOZZLES VACUUM FILLING MACHINE This manual is the property of TENCO s r l Via Arbora 1 16030 Avegno GE Italy Reproduction or disclosure to third party of the cont...

Page 13: ...700 0007 000 Rev 0 Pag 13 Tenco Srl Via Arbora 1 16036 Avegno GE Tel 39 0185 79556 E mail info tenco it Web www tenco it FOUR NOZZLES VACUUM FILLING MACHINE...

Reviews: