INSTALLATION INSTRUCTIONS
Gas Furnace: (F/G)MAC
6
440 01 4201 01
Specifications subject to change without notice.
Figure 2
Dimensions
(F/G9MAC)
FURNACE SIZE
A
B
C
D
SHIP WT.
LB (KG)
CABINET WIDTH
OUTLET WIDTH
BOTTOM
INLET WIDTH
AIR INTAKE
60,000
17
−
1/2 (445)
15
−
7/8 (403)
16 (406)
8 3/4 (222)
154 (69)
80,000
17
−
1/2 (445)
15
−
7/8 (403)
16 (406)
8 3/4 (222)
164 (73)
100,000
21 (533)
19
−
3/8 (492)
19
−
1/2 (495)
10 1/2 (267)
179 (80)
120,000
24
−
1/2 (622)
22
−
7/8 (581)
23 (584)
12 1/4 (311)
203 (91)
NOTE
: Doors may vary by model.
a. For 800 CFM 16
−
in. (406 mm) round or 14
½
x 12
−
in. (368 x 305 mm) rectangle.
b. For 1200 CFM 20
−
in. (508mm round of 14
½
x 19
½
−
in. (368 x 495 mm) rectangle.
c. For 1600 CFM 22
−
in. (559 mm) round or 14
½
x 22 1/16
−
in. (368 x 560 mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Installation Instructions for specific use of single side
inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only return air openings may be
required for airflow requirements above 1800 CFM at 0.5 in. w.c. ESP