Copyright20 Tempest Technology Corporation (Rev: 8.10.2020.1)
17
Clinometer
Indicates the degree of slope of the surface that the MVU is sitting on. Reads both
lateral and longitudinal slope. MVU scissors lift
must not
be elevated when the
clinometer exceeds either of the slope parameters listed below:
IMPORTANT
:
Maximum lateral slope is two degrees (2
O
) in either direction.
Maximum
longitudinal
slope is five degrees (5
O
) in either direction.
Master Disconnect
The Master Disconnect turns off all power to the control panel. It is located on the right
hand side of the MVU control panel. The Master Disconnect Switch should be OFF
during storage of MVU.