LIZA Enclosure User Manual
page 10
3.2 Remove the Fan Control Cover, and pull AC and Signal control wires through conduit entries, as
shown here.
Power Connections – Single or Split Feed
Single Feed:
Enclosure and projector are on the same power circuit. The enclosure will move air in the
event that the enclosure gets warm when the projector is off (recommended). The circuit must be
fused to protect the projector load plus 40W.
Split Feed:
Enclosure and projector are on separate power circuits. It is the user’s responsibility to
ensure that the enclosure power is on when the projector is in use. In Split feed operation the LINE
circuit will pull 40W maximum and the SPLIT circuit must be protected to suit the projector load.
Replace the Controller Cover.
LIZA Fan Control
Board
IMPORTANT:
Split Feed – you MUST cut
this link at both ends
Signal Conduit
Entry
Power Conduit
Entry
Duplex IEC C13
Outlet
Line: 90-265VAC
Split Feed (Projector Power) 90-265VAC*
Neutral
Protective Ground/Earth
* Split feed is NOT CONNECTED for
Single Feed operation