17
Instructions manual |
www.grupotemper.com
KDP
Remote control
Button
Function
Short impulse mode for load I (CH1)
In this mode Load I(CH1) will on 1sec and off 9sec when
detector detects movement. Detector acts depending on
movement and the pre-set Lux value under short impulse
mode.
To set delay off TIME2 (HVAC)
By pressing corresponding button, the desired swithing off
delay time of load II (CH2) for HVAC can be exactly set, it is
confirmed by flashing of detector
’
s LED for 2sec.
If detector has only one load, TIME2 is invalid.
Short impulse mode for load II (CH2)
In this mode Lo
adⅡ(CH2) will on 5sec and
o
ff 5sec when
detector detects movement. Detector acts depending on
movement regardless of Lux value setting under short impulse
mode.
Troubleshooting
Problem
Possible cause
Suggested solution
Detector fails
to receive
signal
1. Exceed the
transmission range.
2. Low battery power.
3. Detector works
abnormally.
1. Operate within transmission range,
and ensure KDP aims directly to the
detector.
2. Replace a new battery.
3. Check the trouble of detector, then
refer the TROUBLE SHOOTING of
detector manual for reparing.
No signal
1. Low battery power.
2. Press two or more
buttons once.
1. Replace battery.
2. Press one button once.
Fail to transmit
signal
In locked mode.
Unlock the controller.