Instructions manual | 

www.grupotemper.com 

KDP

Remote control

Button

Function

To adjust Lux value

By pressing corresponding button, the selected light level 
threshold is set to presence detector for switching on the 
connected load. Load II (CH2) is independent of Lux value.

To read-in the actual ambient light level

Actual ambient light level can be read-in as threshold for 
switching the connected load, if the provided Lux values do not 
match user

s requirement.

The steps are as below: Press 

 button till detector

s red LED 

flashing to enter into learning mode, learning time is 10sec. 
Then the actual ambient light level is read-in confirmed by 
both load and LED turn on for 5sec to indicate 

KDP

 learning 

successfully and then turn off. Afterwards, it returns to Auto 
mode.
Note: If the ambient light level is out of the range of 10 - 
2000Lux, detector will learn for 10sec, then LED flashes quickly 
for 5sec to indicate KDP learning is failed, and the alternative 
of 10Lux or 2000Lux value will be stored depending on under 
10Lux or above 2000Lux value.

To set delay off TIME1 (Lighting)

By pressing corresponding button, the desired switching off 
delay time of load I(CH1) can be exactly set, it is confirmed by 
flashing of detector

s LED for 2sec.

Test mode

•  By pressing this button to enter into Test mode, it is 

confirmed by flashing of detector

s LED for 2sec. 

Walking through the detection coverage, both load I(CH1) 
and detector

s LED turn on 2sec once detector is triggered 

(Reaction is regardless of Lux value).

•  Load II(CH2) has no reaction in test mode.

Summary of Contents for Koban 0775874

Page 1: ...KDP www grupotemper com Mando a distancia Remote control...

Page 2: ...icas 3 Contenido del embalaje 3 Caracter sticas 3 Consideraciones previas 3 Instalaci n 4 Funci n de los botones 6 Resoluci n de problemas 9 Contents Technical specifications 11 Package contents 11 Fe...

Page 3: ...Adhesivo doble faz Manual Cantidad 1 1 2 1 1 Caracter sticas Con el mando a distancia KDP ya no necesitar de escaleras para programar los detectores de presencia instalados en techos o lugares de dif...

Page 4: ...la Mantenga el mecanismo de bloqueo presionado retire el soporte de la bater a y coloque la nueva pila tipo CR2032 3V DC Aseg rese que la polaridad es correcta y vuleva a colocar el soporte de la pila...

Page 5: ...la pared con los tornillos suministrados Ver FIG 3 A y deslice el mando a distancia en el mismo Ver FIG 3 B Tambi n puede fijar el soporte a la pared mediante el adhesivo de doble faz suministrado Ve...

Page 6: ...8 horas Presionando el bot n la carga del detector se conectar durante 8 horas La carga se desconectar tras un periodo de 8 horas y volver al modo autom tico Presione el bot n de nuevo para salir de...

Page 7: ...el parpadeo del LED durante dos segundos Memorizaci n de ajustes y duplicaci n a otros detectores 1 Configure los valores deseados de luminosidad y tiempo mediante el mando a distancia 2 Presione el b...

Page 8: ...tico Nota si la luz ambiente est fuera del rango 10 2000Lux tras los 10 segundos de aprendizaje el LED del detector parepadear r pidamente durante 5 segundos para indicar que ha fallado y el nivel de...

Page 9: ...corto para la carga I CH1 En este modo la carga II CH2 se encender durante 5 segundos y se apagar durante otros 5 cuando se detecte movimiento El detector actuar de acuerdo al movimiento y el ajuste d...

Page 10: ...10 Instructions manual www grupotemper com KDP Remote control...

Page 11: ...adhesive tape Manual Quantity 1 1 2 1 1 Features No need of climbing ladders the ceiling mounted presence detector can be programmed easily and safely with KDP By pressing button the ambient light lev...

Page 12: ...acement Keep the locking mechanism pressed down and pull out the battery holder then put in a new battery type CR2032 3V DC And please make sure that the polarity is correct then insert the battery ho...

Page 13: ...ix the wall bracket on the wall by attached wood screw See FIG 3 A then slide KDP into it See FIG 3 B Stick the wall bracket on the wall by attached double sided adhesive tape See FIG 4 A then slide K...

Page 14: ...urned on for 8hrs Load will be turned off after 8hrs and return to auto mode Or press ON button again to exit this 8hrs on mode during this period detector will return to auto mode Or switching off po...

Page 15: ...ctor s red LED keeps on for 2sec The previous setting values can be stored and duplicated to other detector 1 Set the desired Lux and time values on one detector by using the remote controller 2 Then...

Page 16: ...for 5sec to indicate learning successfully and then turn off Afterwards it returns to Auto mode Note If the ambient light level is out of the range of 10 2000Lux detector will learn for 10sec then LE...

Page 17: ...se mode for load II CH2 In this mode Load CH2 will on 5sec and off 5sec when detector detects movement Detector acts depending on movement regardless of Lux value setting under short impulse mode Trou...

Page 18: ...18 Instructions manual www grupotemper com KDP Remote control...

Page 19: ...AL S L garantit cet apareil pour le dur e de 2 ann es contre tout d fault de fabrication Pour le service de garantie vous devez pr senter ce re u avec du ticket de caisse ou la facture TEMPER ENERGY I...

Page 20: ...TEMPER ENERGY INTERNATIONAL S L Pol gono industrial de Granda nave 18 33199 Granda Siero Asturias Tel fono 34 902 201 292 Fax 34 902 201 303 Email info grupotemper com Una empresa del grupo...

Reviews: