background image

TC-3200 Lite

Ver. 1.1  ENG

Instruction

 

Manual

Summary of Contents for TC-3200 Lite

Page 1: ...TC 3200 Lite Ver 1 1 ENG Instruction Manual...

Page 2: ...ITE 1 Controller unit specification 7 2 Basic structure of controller 8 3 Check up list and operate order before using the controller 10 4 Operating modes 11 5 Basic Operation 12 6 Function of protect...

Page 3: ...ire Caution If you don t keep the following steps you can get hurt on your body or properties Warning If you don t keep the rule it is possible that you could get hurt These are contents to keep users...

Page 4: ...elps precise control of temperature regardless of environmental change Output Type You can choose either PWM or SSR mode and control it with users optimized envi ronment Color touch LCD and various di...

Page 5: ...tructure of controller USB port Case handler Main switch Main case Control unit Acrylic cover Unit power LED Output 1 LED Output 2 LED Communication LED You can check the status of unit through unit L...

Page 6: ...utomatically worked by manual out mode even if it occur sensor open short and reverse 1 Check Up status of wiring of connector that connected to the Mold and type of thermocouple T C Check up that wir...

Page 7: ...reverse connection this func tion prevents from overheat in mold by stopping output 3 Protective over current function It is a function that is able to stop output and protect heater malfunc tion when...

Page 8: ...le Name Clock It is presented loaded mold file names and time Move set mold file by clicking it Start Stop Start or stop system Stand By Set Standby Mode Boost Set Boost Mode Timer Control Move the ma...

Page 9: ...e Off Status t Zone Auto Tuning Status p Manual PID Control m Manual Output Status You can change the screen page with arrow button when you cannot see the screen because of many Zones You can see the...

Page 10: ...zones on entire screen Output Percent Consumption current Alarm High Alarm Low Zone No Set Temp Present Temp 7 2 3 Digital You can see the operation status of controller with Digital type on the Digi...

Page 11: ...l zones Page change of setting screen This is the button that change setting screen of basic setup Advanced setup 1 and Advanced setup 2 You can set up Advance setup when Lock Mode is released only Zo...

Page 12: ...oft Minute You can run this with Soft Mode to protect heater If it is satisfied the condition below it will output 30 of usage power amount of control for setting minute when power is on and it will p...

Page 13: ...nced setting 2 Stand By Output Users can reduce the setting temperature of machine to the stand by output on pause time and turn back automatically after the pause time So you can save the electric en...

Page 14: ...ge of amount of the control 7 3 2 System setting display Display of Decimal Point You can set how to display of Current Temperature on the Active Screen Ex Display of Decimal Point Yes 200 0 Display o...

Page 15: ...rror LANGUAGE You can change display language according to your language Setting in details It browses setting in details display in order to set details in each setting Administrator You open adminis...

Page 16: ...T C Test open Short Circuit reverse connection Test for T C Heater Test open Short Circuit Test for heater Start When you click the Button screen will be changed to Test Screen and test will start Se...

Page 17: ...ble on chapter 13 and you can solve the problem with referring to Problem and how to handle the problem while you are using the controller when issue is occurred 7 5 2 Changing record It will record a...

Page 18: ...stem record It will record system start or history of loading Mold File 7 6 System information You can check system version or language file version with system infor mation and you can use this for s...

Page 19: ...ached to the end part of cable in order to make it easy to connect disconnect the wire to the mold controller Various kinds of connectors are used depending on load capacities 8 1 Connecting cable 8 2...

Page 20: ...14 EA 8 96 Zone 16 EA 9 108 Zone 18 EA 10 120 Zone 20 EA 11 132 Zone 22 EA 12 144 Zone 24 EA 8 4 Option As for option in wiring separate power lines from that of T C can be selected depending on cust...

Page 21: ...6 Alarm high limit 50 7 Alarm low limit 50 9 4 3 Advanced setting 2 No Menu Value 1 Standby output 75 2 Boost max output 65 3 T C Calibration 0 4 Change zone T C 0 5 Tuning mode Off 6 PID setting Off...

Page 22: ...terminal connection structure 1 GND 2 485 B 3 485 A 4 TC2 5 TC2 6 TC1 7 TC1 8 Earth 9 AC 220V 10 Heater 2 11 Heater 1 13 FUSE 2 2 14 FUSE 2 1 15 FUSE 1 1 16 FUSE 1 2 11 Electric wiring diagram 11 1 24...

Page 23: ...44 45 11 2 380V 440V 3Phase 4 Line Type 11 3 240V 1 Phase 2 Line Type...

Page 24: ...R S and T 5 Left diagram is wiring before the change and Right diagram is wiring after completion After Before 12 2 Re wiring for supply voltage 220V AC from wiring for supply Voltage AC380V 440V 1 Tu...

Page 25: ...scon nected by momen tary over current Replace F 1 fuse 250V 20A 8 error code FU2 Op display F 2 fuse is discon nected by momen tary over current Replace F 2 fuse 250V 20A 9 Temperature rises continuo...

Page 26: ...it 5 TC Re Thermocouple polarity reverse 6 AL Hi High limit alarm 7 AL Lo Low limit alarm 8 HT Op Heater open 9 HT St Heater open 10 TR St Triac short 240 ComErr Communication error 241 TM_OT Communic...

Page 27: ...52 53...

Page 28: ...54 55...

Page 29: ...KoreaDigital Co LTD TempCube Division 707 Ace twin tower 1 212 1 Guro3 Dong Guro Gu Seoul Korea Tel 02 2109 8882 3 Fax 02 2109 8884 Http www TempCube Com...

Reviews: