Parameter Function
Default Value
Range/options
St11-St51
First timing value
900.0
0 to Timing range
St12-St52
Second timing value
900.0
0 to Timing range
PASS
Password to access
0000
0 = No Password
Program
1 - 4999 for adjustable times
5000-9999 for locked times
1996 Override Password
MODE
Timing Mode
dE
dE = Delay On
(ndE1-5)
Selection
int = Interval Time
dd = Delay Off
cct = Cycling Timer
dodo = Delay On Delay Off
rLy = Relay Mode
r nG1
Timing Range
SECS
SECS = 0.1 to 999.9 secs
r nG2
Selection
M-S = 1sec to 99min59sec
H-M = 1min to 99hrs59min
St
Start Mode
CtS
CtS = Close to Start
PtS = Pulse to Start
Ptr = Pulse to Reset
ncYc
Cycle Counter
0000
0000 = Continuous
1-9999 cycles
tdir
Counting Direction
uP
uP or dn = Up or Down
TIMER DISPLAY SELECTION
PRG
SEL
UMT
OP1
OP2
OP3
OP4
OP5
PRG
SEL
UMT
OP1
OP2
OP3
OP4
OP5
PRG
SEL
UMT
OP1
OP2
OP3
OP4
OP5
Power on
Press /\ or V to
view timer being
displayed
Display shows t1, indicat-
ing timer 1 is currently
being displayed. Press
/\ or V to change to next
or previous timer.
Display shows t5,
indicating timer5 will
be displayed if no more
keys are pressed
PRG
SEL
UMT
OP1
OP2
OP3
OP4
OP5
PRG
SEL
UMT
OP1
OP2
OP3
OP4
OP5
PRG
SEL
UMT
OP1
OP2
OP3
OP4
OP5
Display shows t2,
indicating timer2 will
now be displayed. Press
/\ to change to next timer
Display shows t3,
indicating timer3 will
now be displayed. Press
/\ to change to next timer
Display shows t4,
indicating timer4 will
now be displayed. Press
/\ to change to next timer
After approx 2 seconds,
the display will show the
actual value of timer
selected (timer 5 in this
case)
PRG
SEL
UMT
OP1
OP2
OP3
OP4
OP5
PRG
SEL
UMT
OP1
OP2
OP3
OP4
OP5
Green LED indicators
showing energised outputs.
4 digit LED showing set times, process
time parameter messages and options.
DIMENSIONS
N
FRONT PANEL FUNCTIONS
Programming/set up
buttons (see over for
operating details).
88
70
65
Panel cut-out
70 x 45
15
PROGRAM PARAMETERS