![TeMec Drive AZ3 User Manual Download Page 30](http://html.mh-extra.com/html/temec-drive/az3/az3_user-manual_1085339030.webp)
AZ3s USER MANUAL
ST.TEC.054
30 / 60
The value of the controlled variable (variable connected to analog input) is set to 0 if the
value readed from ADC is below the value contained in Zero threshold.
Two selectors (Selector 1 and Selector 2) connect the adapted analog input to the preferred variable.
0: unused.
1: Target velocity (refer to chapter 5.1).
3: Target position (refer to chapter 5.2).
4: Target torque (refer to chapter 5.3).
EXAMPLE: in order to control the speed of the motor through the analog input 1, from -1500 rpm to
1500 rpm, with an input voltage variable form -10V to 10V, the analog input variables must be
configured as follow:
𝑆𝑒𝑙𝑒𝑐𝑡𝑜𝑟 1 = 1
𝑈𝑠𝑒𝑟 𝑟𝑎𝑛𝑔𝑒 1 = 3000
𝑂𝑓𝑓𝑠𝑒𝑡 1 = 0
The other variables can be left to the default values.