AZ
2
USER MANUAL
ST.TEC.003.EN Rev. 2.1
47 / 52
8.8.
Motor specific errors
!
Read carefully the safety precautions reported in 1.6 before modifying any of the
advanced parameters!
The highlighted parameters are accessible only in advanced mode.
Any change to the parameters of these groups take effect only after the drive restart.
For the encoder-disconnected error the configuration parameters are:
Label
Output
Function
Range
Default
value
AE10
Motor 1
If enabled, the drive blocks in case of error
ON / OFF
ON
AE11
Motor 1
Value of the sensitivity – high threshold
1 – 1000
2
AE12
Motor 1
Value of the sensitivity – low threshold
0 – 1000
1
AE13
Motor 1
Delay of the error detection
1 – 2000
[ms]
1000
AE20
Motor 2
If enabled, the drive blocks in case of error
ON / OFF
ON
AE21
Motor 2
Value of the sensitivity – high threshold
1 – 1000
2
AE22
Motor 2
Value of the sensitivity – low threshold
0 – 1000
1
AE23
Motor 2
Delay of the error detection
1 – 2000
[ms]
1000
Table 46: parameters for encoder disconnected error
For the error of open limit loss the configuration parameters are:
Label
Output
Function
Range
Default
value
AP10
Motor 1
If enabled, the drive blocks in case of error
ON / OFF
OFF
AP11
Motor 1
On state
0 – 1
1
AP12
Motor 1
Off state
0 – 0
0
AP13
Motor 1
Delay of the error detection
1 – 5000
[ms]
1000
AP20
Motor 2
If enabled, the drive blocks in case of error
ON / OFF
OFF
AP21
Motor 2
High threshold
1 – 1
1
AP22
Motor 2
Low threshold
0 – 0
0
AP23
Motor 2
Delay of the error detection
1 – 5000
[ms]
1000
Table 47: parameters for open limit loss error
For the error of close limit loss the configuration parameters are:
Label
Output
Function
Range
Default
value
AC10
Motor 1
If enabled, the drive blocks in case of error
ON / OFF
OFF
AC11
Motor 1
On state
0 – 1
1
AC12
Motor 1
Off state
0 – 0
0
AC13
Motor 1
Delay of the error detection
1 – 5000
[ms]
1000
AC20
Motor 2
If enabled, the drive blocks in case of error
ON / OFF
OFF