FIREPLACE INSTALLATION
This list of specific instructions will help you make certain
that every installation operation is done correctly. Complete
the installation steps in the sequence shown.
Local building codes should be consulted in all cases as to
the particular requirements concerning the installation of
factory built fireplaces. Select the location for the fireplace
by taking into consideration the factors previously outlined
in the Planning Ahead section of the manual.
INSTALLING THE FIREBOX
STEP 1. FRAMING THE FIREBOX
When framing the opening for the fireplace, make certain
that the header is the correct height above the surface upon
which the fireplace will sit. The header must be level. The
header and framing may be installed as shown in figure 5
or figure 7 according to the installer's preference.
The entire fireplace can be elevated above the floor to
achieve a raised hearth effect. This can be done by adding
a small platform to achieve the desired height.
The nailing flanges on the side of the firebox were designed
to allow the installation of ½" wallboard or plywood flush
with the face of the firebox.
STEP 2. HEARTH SAFETY STRIP
A Hearth Safety Strip must be installed under the fireplace
when the fireplace is installed on a combustible floor. This
strip must be positioned on the floor to extend 2" under the
fireplace, 2" under hearth extension and 6" on either side of
the fireplace opening at the point where the hearth exten-
sion meets the fireplace. See Figures 4 and 6.
STEP3. INSTALL THE FIREBOX
Install fireplace into the framed opening by setting the unit
directly in front of the opening and then sliding it into the
proper position.
STEP 4. LEVEL THE FIREBOX
Check the level of the fireplace by placing a level on the top
edge of the fireplace face. Shim with sheet metal if neces-
sary.
STEP 5. SECURE THE FIREBOX
Secure the fireplace to the framing. The nailing flanges on
Figure 7
Figure 6
A
B
C
D
E
F
G
H
I
36" models
38 3/4
21 8 7/8 22
38
65
32 1/2
46
14 3/8
39" models 41 13/16 22 8 1/2 29 41 3/4 73 7/16 36 3/4 51 15/16 16 7/16
42" models 44 13/16 22 8 1/2 32 41 3/4 76 1/4 38 1/8
54
17 5/8
Figure 5
Framing Dimensions