background image

TEMA TELECOMUNICAZIONI SRL

                                

               

VoIP Doorphone Interface AA-15IP 

MAS-AA15-REV00EN 

 

 

   

 

 

 

                              Page 5 of 32 

 

1.  PRESENTATION  

 
The  AA-15IP device allows to interface any traditional doorphone (4 or 5 wires) to an IP-PBX in order to  manage 
the  doorphone  from  any  internal  extension or, in  the absence  of  an IP-PBX,  it  can  also  work  with  a  common  SIP 
phone  in  P2P  (Peer-to-Peer)  mode.  When  a  visitor  presses  the  call  button  of  the  existing  doorphone,  AA-15 
generate a  SIP  call  to  a  programmed  extension  number  by  putting  the  visitor  in communication  with  the operator 
who answered, who has the possibility to operate, with a code from the  phone, the relay for opening the entrance 
gate. A second relay can be activated, from the internal telephone as well, for other services. 
 
When an  IP-PBX is present, the calls from the intercom can be routed to an external telephone number, including 
mobile numbers. 
 
The  device  has  an  external  contact  input  that  can  be  used  as  an  alarm  dialer:  when  closed,  AA-15IP  calls  a 
programmed number and alerts the event with a customizable voice message. 
 
If  there  is  no  IP-PBX,  the  basic  functions  (communication  and  gate  opening  relay  activation)  are  obtained  by 
connecting a normal IP-SIP phone and programming AA-15IP in P2P (Peer-to-Peer) mode. 
 
It  is  possible  to  connect  AA-15IP  both  to  the  central  unit  of  the  doorphone  system  or 

directly  to  the  internal 

station (wall-mounted intercom) of the single user.

 

 
AA-15IP  integrates  a 

PoE

  power supply  and  can  therefore  be  powered  on  the  same  cat5/6 LAN  cable  if  coming 

from a PoE switch. Alternatively, an input for external 230Vac power supply is available (Optional). 
 
The  dimensions  76.5x62xH32.5mm  (connectors  excluded)  they  are  extremely  compact  and  the  system  can  be 
fixed to the wall with the included bracket or on a DIN bar with a special accessory (Optional). 

 

Main features 

 

 

Can be connected with all 4-5 wires doorphones models, DIN rail mounting 

 

1 power open-door relay and 1 auxiliary relay 

 

Up to 2 configurable extension numbers (in case of no answer) 

 

3 alternative programmable numbers according to day/night/interval times (need internet access) 

 

Relay: configurable opening and closing contact 

 

Activity display LED 

 

Easy programming via Web browser  

 

Compatible with the most popular IP-PBX brands 

 

Total Management via LAN, integrated Web Server 

Programming,  configuration,  loading  and  listening  of  audio  files,  firmware  update,  audio  volume  adjustment, 
backup, configuration reset, device reboot.   
 

Integration in telephone VoIP SIP and security systems 

AA-15IP  integrates  perfectly  with  VoIP  telephony  systems  (IP-PBX)  with  SIP  protocol  that can  be  registered as a 
normal VoIP phone or in Peer-to-Peer (P2P) mode without a PBX. 
 
 
 
 
 
 
 
 
 
 
 
 

Tested with the most popular PBX brands: 

SIEMENS/UNIFY - AVAYA - ALCATEL – PANASONIC – SAMSUNG - NEC  - 3CX 

LG ERICSSON - WILDIX - AASTRA  - ASCOM - NITSUKO – SELTA - PHILIPS 

MITEL – YEASTAR - ZYCOO – CISCO –  EPYGI ELASTIX – GRANDSTREAM – 

SHORETEL - NORTEL – SWYX – XORCOM – ASTERISK-BASED SYSTEMS 

SOFTPHONE OF DIFFERENT MANUFACTURERS 

Summary of Contents for AA-15IP

Page 1: ...e not supplied 2 The device has been carefully manufactured and tested In any case the product is not recommended for use in situations in which incorrect operating may result in damage to persons and or property 3 We recommend that you carefully read all this manual before starting to use the device 4 Do not expose the device to sunlight and protect it from sources of heat dust humidity and chemi...

Page 2: ...sed out wheeled bin symbol below indicates that this electronic equipment is intended to be disposed in a separate collection and not in an unsorted municipal waste in order to provide for the treatment of WEEE Waste Electrical and Electronic Equipment using best available recovery and recycling techniques Specific treatment for WEEE is indispensable in order to avoid the dispersion of pollutants ...

Page 3: ... 6 Products powered via PoE Power over Ethernet may only be connected with cables coming from the internal network company inside the building are not allowed connections LAN cables coming from outside the building 7 Use for this device only and exclusively original spare parts and consumables supplied by Tema Telecomunicazioni The company is not responsible for damage caused by the use of materia...

Page 4: ...8 7 8 DAY NIGHT INTERVAL COMMAND CODES FOR THE OPERATOR 18 7 9 RELAY AND ALARM SETTINGS 19 7 10 ACQUISITION OF INPUT ALARM CONTACTS 20 7 11 CALL BUTTONS 21 7 12 MESSAGES MANAGEMENT 21 8 MAINTENANCE 22 8 1 SYSTEM 22 8 2 LOGIN CREDENTIALS 23 8 3 DIAGNOSTIC LOG 23 9 APPENDIXES 24 9 1 USE OF THE AUDACITY SOFTWARE FOR AUDIO FILES RECORDING 24 9 2 CABLING OF A UTP RJ45 NETWORK CABLE ACCORDING TO THE STA...

Page 5: ... intercom of the single user AA 15IP integrates a PoE power supply and can therefore be powered on the same cat5 6 LAN cable if coming from a PoE switch Alternatively an input for external 230Vac power supply is available Optional The dimensions 76 5x62xH32 5mm connectors excluded they are extremely compact and the system can be fixed to the wall with the included bracket or on a DIN bar with a sp...

Page 6: ...sence of the IP PBX calls from the doorphone can be routed to external phone numbers including mobile IMPORTANT NOTE the quality of the audio received and transmitted is strictly dependent on the quality of the intercom system the device does NOT correct any disturbances or low audio quality of the existing intercom system but transfers the audio exactly as it receives it 3 PACKING LIST The system...

Page 7: ...available input contact VoIP IP LAN section Integration with the local LAN LAN 100 BaseT Ethernet port with RJ45 connector VoIP connection with SIP protocol both in SIP Proxy Server mode Registration on IP PBX and Peer to Peer possibility of PoE Power over Ethernet power supply 5 TECHNICAL FEATURES Generals Insertion terminals for wiring Possibility of using cables up to 1 5mm2 or AWG16 Number of ...

Page 8: ...larity Auxiliary voltage output RJ45 PoE LAN Cable Auxiliary relay 2 output UTP cable from TAP 8 7 6 5 4 3 2 1 BR WH GR WH BL WH OR WH BR BL GR OR MIC SP LOCK OPENING BUZZER TO THE DOORPHONE Indoor station or central power supply TAP The terminations of the UTP cable coming from the RJ45 socket called TAP must be connected to the terminals of the internal station or to the respective signals of th...

Page 9: ...nternal electronics and converted into VoIP SIP protocols IMPORTANT NOTE the quality of the audio received and transmitted is strictly dependent on the quality of the intercom system the device does NOT correct any disturbances or low audio quality of the existing intercom system but transfers the audio exactly as it receives it Devices powered via PoE Power over Ethernet may only be connected wit...

Page 10: ...owing a code dialed on the internal telephone keypad The device works transparently while maintaining the functionality of the indoor station which can continue to be used normally A second relay is available for other functions An alarm input is available which if closed makes a phone call and sends a message NOTE see the wiring diagrams of other brands and models of interphones in the appendices...

Page 11: ... connect to the web interface of AD635 it is necessary that in the IP addresses configuration of your PC is present the subnet 192 168 0 x where x is any number between 1 and 254 and different from 10 See below how to configure your PC to reach the correct subnet The shown procedure applies to Windows operating systems Open the Windows Control Panel and set the field View by Category Large Icons o...

Page 12: ...member the current TCP IP configuration of your computer for any subsequent restore of the correct parameters Click Use the following IP address and type in the appropriate field the following IP address 192 168 0 11 instead of 11 used in the example it is possible to enter any number between 1 and 254 but excluding the 10 which is the default address of the system to be programmed In the Subnet M...

Page 13: ...ossbile to change the administrative password for the maximum safety of your device Once logged in it is possbile to change the administrative password for the maximum safety of your device see par 8 2 The use is very simple and intuitive the menu for selecting the functions to be programmed is always visible on the left while the configuration mask active at that time is shown on the right Each c...

Page 14: ...reboot the system and if necessary change the network segment of your computer so that it can connect to the new address IP address specify the IP address you want to assign to AA 15 Subnet mask indicate the subnet mask to be assigned to AA 15 Default gateway indicate the gateway that can enable AA 15 to access to internet Primary and secondary DNS server indicate the addresses of two DNS servers ...

Page 15: ...e 5060 but some stations use a different port Domain enter the domain to which register the system Outbound proxy some PBXs require that the extension number to call is followed by the proxy address In most cases this field can be left empty Local SIP port generally the 5060 port is used but it is possible to specify a different number i e for particular routing tables User password credentials fo...

Page 16: ...es an incoming call if this field is programmed the audio will not be connected until the user will enter the right connection code Monitoring code as in the previous case for incoming calls the audio is not connected until the code is entered but in this case only the audio from microphone is connected a sort of monitor function it is possible to hear the audio near the doorphone Calling speaker ...

Page 17: ...wer via DTMF type the code corresponding to the selected mode The codes must consist of 2 characters Time bands in the case of automatic operation it is possible to enter up to 5 bands per day If a field is left blank it is unused and the previous corresponding band will be used Time zone time zone of the location where the installation is made 1 for Italy Latitude Longitude Geographical decimal c...

Page 18: ...witch to each mode based on a time schedule When the visitor presses the button a call is made to one of the PBX extensions associated with the pressed button The numbers that will be called may differ depending on the operating mode in which the system is located Day Night Interval mode see par 7 6 In the case of expansion with a keyboard this allows the desired number to be dialed directly or to...

Page 19: ... system based on the current time and location of the installation the exact time should be obtained from the internet PHONE activation relay activation code to dial from the extension of the PBX 2 characters required Activation time activation time of the relay Activation delay for relay 2 after how many seconds you have to turn with respect to the activation of relay 1 if set in after Relay 1 Cl...

Page 20: ...essage to be reproduced during the call A neutral message Alarm1 is reproduced as standard but the text can be customized It is possible to associate a phone number or an IP address that will be called during the alarm phase The closure of an external contact triggers the signaling sequence but it is also possible to reverse this logic so the signaling can occur following the opening of the contac...

Page 21: ...to 2 numbers registered in the IP PBX to contact P2P Peer to Peer call in the absence of an IP PBX it is possible to insert in the windows the IP address of the terminal to be called a P2P call will therefore be established when Key 1 is pressed NOTE it should be noted that the AA 15 system works in a transparent way and does not affect the functionality of the intercom system this means that the ...

Page 22: ...urrent settings to restore them in case of a programming error or device replacement Reset to factory settings all settings are lost and reset to factory defaults You are prompted to confirm the operation Device reboot reboot as if it were taken away and put back power Useful in case you have not physically present in front of the device and it needs to restart it You are prompted to confirm the o...

Page 23: ...rd should be introduced twice for confirmation If for any reason your password was forgotten it is possible to reset it to the default closing a jumper inside the device see par 0 8 3 Diagnostic log To identify small configuration problems it is possible to activate a diagnostic summary on the activity of the two VoIP channels of the device Simply connect via TCP port 9991 with Telnet or a termina...

Page 24: ... the previous recording simply select the audio track crawl from start to finish press the Delete button and repeat the recording With this procedure it is also possible to delete small parts of silence or sound inside the track 3 To save the recording click on File Export Audio give a name and select in the WAV Microsoft 16 bit PCM format drop down list The saved file is ready to be used on all d...

Page 25: ...ires some additional millimeter Hold with one hand the wires and with the other pull the smoothing sheath Straighten the wires previously individually pair twisted Compose the color sequence following the pattern Level the length of the cables into place Insert the tightened wires into RJ45 connector holding them between your fingers until they are channeled into the guides inside the connector it...

Page 26: ... Page 26 of 32 9 3 Connection with URMET intercom 8 7 6 5 4 3 2 1 UTP cable from TAP Switch PoE IP PBX SIP SERVER IP SIP Phone Alarm contact input Second auxiliary relay 12Vdc Vac Input if PoE not available 12Vdc Max 200mA Output POWER SUPPLY DOOR OPENER AMPLIFIED DOOR STATION ...

Page 27: ...Interface AA 15IP MAS AA15 REV00EN Page 27 of 32 9 4 Connection with URMET mod 1130 intercom 8 7 6 5 4 3 2 1 UTP cable from TAP INTERCOMS TO SUBSEQUENT INTERCOMS PUSH BUTTON PANEL AND EXTERNAL UNIT MAINS POWER SUPPLY LOCK OPENING ELECTRIC LOCK ...

Page 28: ...OMUNICAZIONI SRL VoIP Doorphone Interface AA 15IP MAS AA15 REV00EN Page 28 of 32 9 5 Connection with BPT intercom 1 2 3 4 5 6 7 8 UTP cable from TAP AMPLIFIED DOOR STATION POWER SUPPLY DOORBELL BUTTON DOOR OPENER ...

Page 29: ...TELECOMUNICAZIONI SRL VoIP Doorphone Interface AA 15IP MAS AA15 REV00EN Page 29 of 32 9 6 Connection with TERRANEO intercom 1 2 3 4 5 6 7 8 UTP cable from TAP POWER SUPPLY AMPLIFIED DOOR STATION DOOR OPENER ...

Page 30: ...TEMA TELECOMUNICAZIONI SRL VoIP Doorphone Interface AA 15IP MAS AA15 REV00EN Page 30 of 32 9 7 Connection with FARFISA intercom 9 8 Connection with COMELIT intercom ...

Page 31: ... In any case the internal intercom station remains operational since AA 15IP is transparent and works in parallel I can t get to the place where I have to install AA 15 with a UTP cable can I use a Wi Fi link Yes AA 15 is a normal LAN network terminal in this case you need a client access point with the RJ45 LAN output towards AA 15 and a power supply for example the plug model T7012L or for DIN r...

Page 32: ...TEMA TELECOMUNICAZIONI SRL VoIP Doorphone Interface AA 15IP MAS AA15 REV00EN Page 32 of 32 NOTES ...

Reviews: