TEMA TELECOMUNICAZIONI SRL
VoIP Doorphone Interface AA-15IP
MAS-AA15-REV00EN
Page 19 of 32
7.9.
Relay and alarm settings
On this page it is possible to choose the operating mode of the two internal device relays and the operating mode
for external inputs:
•
Mode
: sets the function to be associated to the relay. It is possible to choose between:
1 Electric lock: is activated only upon receiving the activation code.
2 In call: is activated when a call is in progress and until the door phone does not come back to idle
3 In call + timer: it activated when a call is in progress and for the activation time
4 Pressure button: you press any key relay is activated for the time set
Only for the relay 2
5 After relay 1: When you operate the relay 1, relay 2 is activated also for the time set
6 Twilight: In this mode the relay is activated 30 minutes before sunset and 30 minutes after sunrise.
The calculation of sunrise and sunset is done automatically by the system based on the current
time and location of the installation (the exact time should be obtained from the internet).
•
PHONE activation
: relay activation code to dial from the extension of the PBX (2 characters required)
•
Activation time
: activation time of the relay
•
Activation delay
: for relay 2, after how many seconds you have to turn with respect to the activation of relay
1 (if set in "after Relay 1")
•
Close call
: by setting this option, your call is immediately hang up when the relay is activated
Commands described here by default will have these codes:
DTMF
Command
Function
Description
#1
Activate the door
opener contact of relay 1
Used to activate the electric lock connected to the first
relay during communication, it is a 2-digit code, by
default #1.
#2
Activate the door
opener contact of relay 2
Used
to
activate
the
second
relay
during
communication, it is a 2-digit code, by default #2.
#5
Conversation time extension
Continuing the conversation with the visitor, at the
notice of AA-15 regarding the expiration of the same, it
is possible to reload the original time to continue the
conversation. AA-15 warns with some tones 30
seconds before closing.