56044702 13
© 2012 Telular Corporation
1.
Connect the black and red leads to the GND and PWR
terminals of the alarm panel. The specific terminals used on
the panel will depend on the panel make and model.
2.
Connect the black and red leads to the GND and PWR
terminals on the TG-1 Express.
3.
Reconnect the alarm panel’s power supply, and ensure that
the PWR light (LED 8) on the TG-1 Express is illuminated.
To connect power to the TG-1 Express using the POTS connection:
1.
Using a standard RJ-31X to spaded lead cable, connect the
orange and blue leads to the GND and PWR terminals of the
alarm panel respectively.
2.
Connect the remaining leads to the Telco terminals in the
alarm panel, per the panel’s instruction.
3.
Connect the other end of the cable to the RJ-45 jack on the
TG-1 Express.
Reconnect the alarm panel’s power supply, and ensure that the PWR
indicator (LED 8) on the TG-1 Express is illuminated.
Recommended Wire Size Length Not to Exceed
18
ga
20
ft
16
ga
40
ft
14
ga
60
ft
Connect Antenna and Temporarily Place Unit
The Telguard is supplied with an antenna. In most cases the antenna
may be mounted directly to the Telguard. If a stronger radio signal is
required, the antenna must be moved to a better signal location using
a Telular antenna cable and bracket accessory (sold separately). The
performance of the Telguard antenna may be affected by the wall
material and materials contained within the wall chosen for mounting.
These effects may not be clearly identified by RSSI monitoring alone.
The wall materials may have a more pronounced effect on the
antenna’s transmit band performance.