Phonecell
®
SX5T CDMA
10
User Manual
DATA FEATURES
When connected to a personal computer (PC), the SX5 is capable of sending and receiving digi-
tal fax and data, sending and receiving email communications, and accessing the Internet. Data
speeds may vary depending upon your cellular network.
Connect SX5 to a Computer
Use a data cable to connect the data port on the SX5 to the appropriate data port on your PC -
see
Figure: 20
Configure PC for Circuit Switched Data
Requirements
• Active CDMA account with your network service
provider including a Data/Fax facility
• Windows (version 95/98 or later)
• PC with a serial or USB Port.
Modem Setup
1. Power on your PC/laptop.
2. Access the Control Panel, then select the Modems option.
3. Install a new modem device for the SX5 with the following specifications:
Modem Type:
Standard 19200 bps Modem
Maximum speed of serial port:
19,200
Data bits:
8
Parity:
None
Stop bits:
1
Use Flow Control:
Enable this option and select Hardware [RTS/CTS]
Extra settings:
AT & D1
Automatic Baud Rate Fallback Control
The SX5 supports an automatic fallback to 19,200 bps when errors are detected in the data
stream. This is useful for applications such as PC digital fax because most PC fax applications
require a 19,200 bps baud rate on the serial port.
Enabling Fallback
Enable this feature when you have an application that uses a port speed of 19,200 bps. When
the SX5 has a port speed that does not match the port speed on the PC, errors will be detected.
When these errors are detected, the SX5 will adjust the port speed to 19,200 bps, thus matching
the PC application rate of 19,200 bps. It does not matter if the SX5's port speed is higher or
lower than 19,200 bps, the SX5 will still be adjust the rate to 19,200 bps.
NOTE
: The SX5 does not support autobauding and will only adjust the port speed to 19,200 bps
under the above conditions. No other rate will be automatically set.
Press:
# * 132 * 1 # ( <default setting> )
When to Disable Fallback
If you mainly use the SX5 for GPRS data, then disable fallback of the port rate. This will allow
some errors in the data stream without effecting a change in port speed on the SX5.
Press:
# * 132 * 0 #
Baud Rate AT Commands
The SX5 will accept AT commands to setup the port speed. If you want to change the SX5 port
speed for a session or keep the change permanent, or if you just want to see the profile settings,
use the following AT commands from a terminal application (like HyperTerminal).
NOTE: Make sure DTE Fallback is OFF before making changes to the baud rate.
Figure 20 -
Data Port on the SX5
Data Port