How to Set the Access Overload Class (ACCOLC)
Use the following key sequence to set the ACCOLC:
Press:
#
*
2
*
< ACCOLC > #
The
< >
brackets represent the
2-digit
ACCOLC. You must enter a
2-digit value between
00
and
15
, otherwise the FWT will not update
or store this value; the existing stored parameter will remain.
(For
example, to program the FWT for ACCOLC 8, enter: # * 2 * 08 #.)
How to Set the Access Method (EX) Option
Use the following key sequence to set the EX option:
Press:
#
*
3
*
<EX option> #
The
< >
brackets represent the
1-digit
EX option:
enter:
1
if the FWT must always send the full MIN
(Mobile
Identification Number)
when accessing the system
enter:
0
if not.
You must enter either
0
or
1
, otherwise the FWT will not update or
store this value; the existing stored parameter will remain. The factory
default setting is 1.
How to Set the Roam Option
Use the following key sequence to set the Roam option:
Press:
#
*
6
*
<Roam option> #
The
< >
brackets represent the
1-digit
Roam option:
enter:
0
to enable roaming
enter:
1
to disable roaming.
You must enter either
0
or
1
, otherwise the FWT will not update or
store this value; the existing stored parameter will remain. The factory
default setting is
0
.
How to Set the Dial Tone After Remote On-Hook Option
Use the following key sequence to set the Dial Tone After Remote
On-Hook option:
Press:
#
*
8
*
<Dial Tone option> #
The
< >
brackets represent the
1-digit
dial tone option:
enter:
0
for no dial tone after a remote on-hook
enter:
1
to enable dial tone after remote on-hook.
You must enter either
0
or
1
, otherwise the FWT will not update or
store this value; the existing stored parameter will remain. The factory
default setting is
1
.
Technician Programming Commands – Continued