84
Minimal
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
0
I/O#1 property parameter priority
I/O#1 averaging length (ID=50005)
S8
6.12.6
I/O#1 averaging length (ID=50005)
Parameter defines I/O property sample length to average. If no averaging needed default
value
is 1.
Minimum
value
Maximum
value
Recommende
d value
Goes with (depends on)
parameters
Value
type
0
2147483647
10
I/O#1 property parameter priority
S32
6.13
I\O elements parameters and types.
Priority:
0 – disabled, 1 – low, 2 – high, 3 – panic.
Operand:
0 – On Exit, 1 – On Entrance, 2 – On Both, 3 – Monitoring, 4 – On Hysteresis, 5 –
On Change, 6 – On Delta Change.
Event only:
0 – No, 1 – Yes.
Parameter
ID
Parameter
Type
Default value
Value range
Parameter name
Min
Max
50000
Uint8
1
0
3
Ignition Priority
50001
Uint8
5
0
6
Ignition Operand
50002
Uint8
0
0
1
Ignition High level
50003
Uint8
0
0
1
Ignition Low level
50004
Uint8
0
0
1
Ignition Event only
50005
Uint16
10
0
65535
Ignition Average
7000
Uint8
0
0
10
Send SMS
8000
String
0
0
160
SMS Text
50010
Uint8
1
0
3
Movement Priority
50011
Uint8
5
0
6
Movement Operand
50012
Uint8
0
0
1
Movement High level
50013
Uint8
0
0
1
Movement Low level
50014
Uint8
0
0
1
Movement Event only
50015
Uint16
1
0
65535
Movement Average
7001
Uint8
0
0
10
Send SMS
8001
String
0
0
160
SMS Text
50020
Uint8
1
0
3
Data Mode Priority