![Teltonika FMB900 User Manual Download Page 73](http://html1.mh-extra.com/html/teltonika/fmb900/fmb900_user-manual_1084776073.webp)
73
value
value
value
parameters
type
0.5
10
2.5
Float
6.7.4
Max Cornering (ID=11006)
It is max allowed cornering angle which can be reached while cornering without triggering
harsh cornering event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0.5
10
2.1
U16
6.7.5
Green/Eco driving (ID=11007)
Choose between Eco driving(accelerometer) and Green driving(gps). 0 – GPS, 1 –
Accelerometer
Minimum
value
Maximum
value
Default value
Goes with (depends on)
parameters
Value
type
0
1
0
U16
6.7.6
Green driving digital output control settings (ID=11003)
Sets digital output off (0) or on (1)
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
0
Float
6.7.7
Green driving Digital output on duration (ID=11001)
Output ON duration in mili-seconds
Minimum
value
Maximum
value
default value
Goes with (depends on)
parameters
Value
type
0
21474836
47
200
Float
6.7.8
Green driving Digital output off duration (ID=11002)
Output OFF duration in in mili-seconds
Minimum
value
Maximum
value
default value
Goes with (depends on)
parameters
Value
type
0
21474836
47
200
Float
6.7.9
Overspeeding priority (ID=11100)
Defines priority of overspeeding scenario:
0 – disabled, 1 – low, 2 – high, 3 – panic
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
3
-
U8