Parameter no 17 - Send report on change of power consumption (%)
This parameter will send a power report automatically if the power value
changes of x % compared to the last report.
Default value: 10 %
Size: 1 byte
Possible values: 0: Disabled, 1-100: %
Parameter no 101 - Power (W) report interval
This parameter defines the period of sending power reports
Default value: 600 seconds
Size: 4 byte
Possible values: 0: Disabled, 5-2678400 seconds
Parameter no 102 - Energy (kWh) report interval
This parameter defines the period of sending energy reports
Default value: 3600 seconds
Size: 4 byte
Possible values: 0: Disabled, 5-2678400 seconds
Parameter no 103 - Voltage (V) report interval
This parameter defines the period of sending voltage reports
Default value: 0 (Disabled)
Size: 4 byte
Possible values: 0: Disabled, 5-2678400 seconds
Parameter no 104 - Current (A) report interval
This parameter defines the period of sending current reports
Default value: 0 (Disabled)
Size: 4 byte
Possible values: 0: Disabled, 5-2678400 seconds