Configurations 

By changing configurations, you are able to change various settings in the device. This can 
be done from the Z-Wave gateway/controller,

 if supported.

 

These settings are available in this device: 
 

Parameter no 1 - Overcurrent protection 

If the current exceeds 16A for more than 5 sec, the load will be switched off. 
Default value: 1 (Enable) 
Size: 1 byte 
Possible values: 0: Disabled, 1: Enabled 
 

Parameter no 2 - Remember device status after power failure. 

Define how the plug will react after the power supply is back on. 
Default value: 0 (remember status) 
Size: 1 byte 
Possible values: 0: Remember status, 1: Always on 2: Always off. 
 
 

Parameter no 3 - Send status in Lifeline when Load status change 

Smart Plug can send notifications to associated devices in Lifeline when the status of the 
plug is changed 
Default value: 1 (Send Basic Report) 
Size: 1 byte 
Possible values: 0: Disabled, 1: Send Basic Report, 2: Send Basic Report only when Load 
status is not changed by Z-Wave Command. 
 

Parameter no 4 - LED Indicator 

Configure LED mode 
Default value: 0 (The LED follows the load status.) 
Size: 1 byte 
Possible values: 0: The LED follows the load status, 1: When operating plug, the LED is lit 
for 5 seconds 
 

Parameter no 16 - Send report on change of power consumption (W) 

This parameter will send a power report automatically if the power value 
changes of x W (Watts) compared to the last report. 
Default value: 50 W 
Size: 2 byte 
Possible values: 0: Disabled,  
1-2500: Watts 
 
 

 

 