Configurations
By changing configurations, you are able to change various settings in the device. This can
be done from the Z-Wave gateway/controller,
if supported.
These settings are available in this device:
Parameter no 1 - Overcurrent protection
If the current exceeds 16A for more than 5 sec, the load will be switched off.
Default value: 1 (Enable)
Size: 1 byte
Possible values: 0: Disabled, 1: Enabled
Parameter no 2 - Remember device status after power failure.
Define how the plug will react after the power supply is back on.
Default value: 0 (remember status)
Size: 1 byte
Possible values: 0: Remember status, 1: Always on 2: Always off.
Parameter no 3 - Send status in Lifeline when Load status change
Smart Plug can send notifications to associated devices in Lifeline when the status of the
plug is changed
Default value: 1 (Send Basic Report)
Size: 1 byte
Possible values: 0: Disabled, 1: Send Basic Report, 2: Send Basic Report only when Load
status is not changed by Z-Wave Command.
Parameter no 4 - LED Indicator
Configure LED mode
Default value: 0 (The LED follows the load status.)
Size: 1 byte
Possible values: 0: The LED follows the load status, 1: When operating plug, the LED is lit
for 5 seconds
Parameter no 16 - Send report on change of power consumption (W)
This parameter will send a power report automatically if the power value
changes of x W (Watts) compared to the last report.
Default value: 50 W
Size: 2 byte
Possible values: 0: Disabled,
1-2500: Watts