18
6.7.5 Alarm
settings
•
Arm/Disarm method
: arming and disarming can be performed with external unit
(access keypad, key switch, radio controller etc.), and through phone. For
arming/disarming with external unit one (Z4) or two (Z3 and Z4) inputs can be used
depending on switching signal:
o
0 - Always Armed
: it is not necessary to arm/disarm the module when used as
transmitter device. In this case select this mode and therefore all four inputs will
be available for signal reception and the module will be armed permanently.
o
1 - Using Switch
: arming and disarming is performed with switch or relay
contact where one state of the switch (or compliant relay) arms, the other state
disarms the module. Closed contact on input Z4 (to V-) arms, opening of this
contact performs disarm. In this case input Z4 cannot be used as zone input.
o
2 - Using Switch
: this mode corresponds to previous one but operates the
system inversely (closed contact disarms, open contact arms the module).
o
3 - One kind of impulse
: arms the system with a closed contact impulse on
input Z4 (to V-) and performs disarm with next closed contact impulse on the
same input.
o
4 - Two kinds of impulses
: Select this mode when arming and disarming is
performed by closed contact impulses on two different inputs. Such is e.g. a
rolling code RC module receiver where one relay is activated for a short time as
a result of pressing the arming button and a second relay is activated as a result
of pressing the disarming button. Closed contact impulse applied on input Z3 (to
V-) arms, also closed contact impulse applied to input Z4 (to V-) disarms the
system. In this mode inputs Z3 and Z4 cannot be used for zone function
according to the meaning.
o
5 - Two kinds of impulses
: corresponds to the previous mode but the arming
and disarming is performed by impulsive opening of the closed contacts on
inputs Z3 respectively Z4 (to V-).
Note: in modes 0, 1 and 2 arming and disarming through phone is not available.