7
5.1.4 SIM ”A” / SIM ”B” GPRS settings
SIM ”A”:
the network belonging to SIM card “A” (placed on the right side of the panel)
SIM ”B”:
the network belonging to SIM card “B” (placed on the left side of the panel)
APN name:
internet access point name (belongs to the SIM card, is provided by the
mobile service provider)
User
and
password:
user and password for the APN (necessary only if requested by the
mobile service provider)
PIN:
the module
supports PIN code usage on the SIM cards inserted in sockets SIM “A”
and SIM “B”. If you wish to use this function, enter the PIN code here and enable PIN
code request on the SIM card. The module will provide the PIN code upon each power
up and upon daily restarts when the PIN is requested by the SIM card.
Attention!
The SIM card will become blocked if you enter the wrong PIN code!
Thereafter it can be unlocked by inserting in a cell phone and entering the PUK code.
Receiver
settings:
Attention!
For system safety it is mandatory to configure the IP addresses in pairs,
which means if IP
A
is set,
B
must also be set and vice versa!
Primary 1A, 2A:
the primary receivers belonging to SIM ”A” network
Primary 1B, 2B:
the primary receivers belonging to SIM ”B” network
Comment:
in this textbox you can add a name to the given receiver. The module does
not use the name entered here, but it is saved with the settings as informative data for an
easier system overview.
IP address:
the IP address of the given receiver
Port:
the port number that belongs to the given IP address
Account ID.:
the user account ID which the module uses when sending events towards
the receiver found on the given IP address
Test freq:
the test report frequency in seconds (60…3600s). The module sends GPRS
test report using the sending frequency set here to verify the connection with the receiver
on the given IP address.
Attention!
The lower the value set, the higher the data traffic will be!
Protocol:
select the appropriate communication protocol from the drop-down list for the
receiver available on the given IP address.
Available protocols:
TELLMon_TCP
,
TELLMon_UDP
,
AMR-08
and
ENIGMA II
.
The UDP protocol allows for less data traffic.