![Telit Wireless Solutions BlueMod+S42/AI Hardware User'S Manual Download Page 43](http://html1.mh-extra.com/html/telit-wireless-solutions/bluemod-s42-ai/bluemod-s42-ai_hardware-users-manual_1083615043.webp)
S42 Hardware User Guide
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.
Page 43 of 62
The following table shows the average power consumption of S42operating in the
peripheral device role.
VSUP = 3,0V, T
amb
= 25°C, all GPIO lines left open, SLCK: 32,768 kHz
Condition
Radio active
Note Slow clock
SLCK
Current Consumption
Unit
Tx power (dBm)
(8)
max (+4)
min (-20)
I
Avg
I
Avg
Standby, Advertising on 3 channels,
advertising interval: 1,28s,UICP not active
or
serial interface up
(5)
internal
(7
ext. Crystal
1,2
1,2
1,2
1,2
mA
Standby, Advertising on 3 channels,
advertising interval: 1,28s,UICP active
and
serial interface down
(1)
internal
(7)
ext. Crystal
17,6
16,0
14,5
12,9
µA
Connected, connection interval:
1,28s,UICP not active
or
serial interface
up, no data traffic
(5)
internal
(7)
ext. Crystal
1,2
1,2
1,2
1,2
mA
Connected, connection interval:
1,28s,UICP active
and
serial interface
down
(1)
internal
(7)
ext. Crystal
10,4
8,7
10,1
8,4
µA
Connected, connection interval: 7,5 ms,
no data traffic
(2,3,6)
1,6
1,5
mA
Connected, connection interval: 7,5 ms,
data traffic 115 kbit/s at the serial port,
central to peripheral
(2,6,9)
tbd
tbd
mA
Connected, connection interval: 7,5 ms,
data traffic 115 kbit/s at the serial port,
peripheral to central
(2,6,9)
tbd
tbd
mA
Connected, connection interval: 40 ms,
no data traffic
(2,4,6)
1,3
1,3
mA
Connected, connection interval: 37,5ms,
data traffic 115 kbit/s at the serial port,
peripheral to central
(2,4,6,
9)
tbd
tbd
mA
Notes
(1)
UART-CTS#, IUR-IN#, UART-RXD driven to CMOS high level, all UART output lines left open
(2)
connection parameters are setup by the central device when connection is established
(3)
no data to be transmitted, central device sends an empty packet (80 bit) peripheral device answers (empty packet: 80 bit)
(4)
these are a typical connection parameters used by an iPhone, iPad or iPad mini device in the central device role
(5)
UART-inputs connected to GND or VSUP; UART output lines left open
(6)
same current consumption w. internal or external slow clock
(7)
RC oscillator internal to nRF52832, periodically trimmed by S-device
(8)
TX power as set by AT command
(9)
Effective Data throughput lower due to flow control in older FW versions
lower current consumption S
Table 16: Supply Current BLE Terminal I/O Profile, Peripheral Device Role