intercom line. If the intercom system is not terminated, the level of intercom line will be too high,
and the system stability will be influenced. However, only one termination point is allowed within
same intercom line. If multiple termination points are used incorrectly, the driving load will be
aggravated, and the level of intercom line will be too low.
This switch is set to ON position by factory default. Before using, you should set it to ON or
OFF position according to the actual connection of intercom line.
Note: When TM-200 connects more than ten ends, this switch can be set as OFF.
27. AC Power Connection
Input 90V-260V, 50-60Hz AC, and the power consumption is less than 45VA.
28. Program Input
XLR-3F balanced input.The pinout of the Program Input connector is as follows:
Pin 1 --- Common (Shield)
Pin 2 --- + Audio
Pin 3 --- - Audio
29. Announce Out
This connector is 3-pin XLR male. 0dBu balanced output.
The pinout of Announce Out is as follows:
Pin 1 --- Common (Shield)
Pin 2 --- +Audio
Pin 3 --- -Audio
IV. Installation and cable
1. Installation
TM-200 main workstation adopts 19-inches 1U cabinet, and this workstation can be mounted on
rack or placed on desktop. If it is placed on desktop, it is required to adhere 4 rubber foot pads
provided with machine to four corners at the bottom of cabinet with double-face adhesive tape.
2. Intercom cable
A). Rules for cable selection
TELIKOU intercom system adopts double-core shielded audio cable, one core is used for
transmitting audio signal, another core is used for transmitting DC power or control signal, and the
shielded layer is used as common line for audio and power supply. To decrease resistance of
common line and crosstalk interference, the cable with larger cross section area should be used.