The last 4 digits of the IMEI are therefore the password for your device and should be kept secretly from your side. 
The IMEI number cannot be changed! You can also change the password for security relevant cases, but please 

bare in mind that each command – also the reset to the factory status- will presumes the knowledge of this 

password. 
Control Commands via SMS: 
Control commands via SMS will only be executed, if the phone number of the sender has been communicated to 

the STD35 before. Control commands 

don’t need

 a password. 

All command (with exception of R: and ST?) have to be terminated with a dot! 
All commands can be sent in one SMS, separated one from the other by the terminating dot. 

 

The indications of the seconds can have 1-5 digits. Valid indications are e.g.: 1 or 90 or 99999, that means there 

won’t be put leading Zeros before the digits (e.g. “O1:90”. This is euiqvalent of 90 seconds). 

 

Please pay attention to the difference between the number 0 and the letter O! (“O1ON.” Contains two times 

the letter O, whereas “O1:0” contains once the letter O and once the number 0). 

 

Basic functions 

  After having been called from the assigned („stored“, pls. See configuration call) mobile phone, the relay 1 

switches for a second. 

  When the digital input1 will be activated for a second, the STD35 sends a SMS with the content „EVENT 

ALARM 1“ to the assigned mobile phone. 

  When the digital input2 will be activated for a second, the STD35 sends a SMS with the content „EVENT 

ALARM 2“ to the assigned mobile phone. 

  The same is certainly valid for the inputs 3 to 5. 

Switching via SMS 

  After having received a SMS with the content „O1ON.“ (=Output 1 ON) from the assigned mobile phone, the 

relay 1 will switch for a second. In case of a SMS “O2ON.” The relay 2 will switch for a second.  

  The same is certainly valid as well for the outputs “relay 3 to relay 5”. 

  In the case that the switching time has been put to 0 (number 0), the relays switch permanently to the other 

status. 

Configuration SMS 

  The configuration SMS is valid, only if beginning with the 4 digit password. Teh CLIP of each of the 

configuration SMS will, if the password is correct, be logged automatically as a new administrator. Therefore it 

has to be considered, that the configuration only is executed from the mobile phone of the administrator. 

  With a SMS having the content „O1:xxxxx.“ (character O= (xxxxx = seconds) the switching times of the relays 

can be configured. The STD35 will keep these configurations even after the cut-off from the supply voltage. 

  In case that the switching time for a relay has been put to 0, the STD35 will, at each new call, switch the related 

relay permanently. Has the relay been active before, it will go to inactive and vice versa. 

  

In this case also a SMS containing “O1ON.” from the assigned mobile phone will switch the relay 1 on 

permanently. A SMS with the content “O1OFF.” will then switch the relay 1 again off permanently. Accordingly 

the relays 2 to 5 will react on SMS messages which contain “OxON.” And “OxOFF.” (x=2...5). 

 

  By a SMS with the content e.g. “I1:xxx.” (xxx=seconds) the times can be programmed for the five inputs, during 

which these inputs have to be active, before the STD35 will send out an alarm SMS. 

The inputs 2 to 5 show the identical behavior. 

 

  By a SMS with the content e.g. “V1:x.” Or “V2:x.” (x = 1 oder 0) the polarity of the inputs can be inverted. In 

case of x=1 there will be sent a alarm SMS, if the input was deactivated longer then the configured time. For 

the inputs 3 to 5 equivalent proceeding is valid (e.g. V4:x.). 

 

 

Summary of Contents for STD35

Page 1: ...cording to DIN VDE 0869 and obliged to hand out all necessary documents with the device and to indicate his name and address Devices which are made out of modules have to be considered as an industrial product from the safety perspective During use of the STD35 Short Messages SMS can be generated automatically Costs may occur for you by this SMS traffic Safety Instructions When using products whic...

Page 2: ...ltage is 250V AC alternating current The maximum switching power per relay is 6A depending on the width of the PCB tracks No special operation position of the device has to be observed When installing the device make sure that the supply cable has a sufficient diameter During operation the temperature has to be between 20 and 55 Celsius In case of condensation allow a period of about 2 hours for a...

Page 3: ...sed SIM card of a GSM network provider on which the PIN has been put to 0000 To change the PIN accordingly you can use a regular mobile phone Please get the proceeding for Pin change out of the corresponding user manual of your mobile phone In case of using a SIM card with another PIN than 0000 the STD35 will use a wrong PIN during each power on which leads to blocking of the SIM card after the 3r...

Page 4: ...private call has to be switched off This is a configuration that you can settle on your mobile phone in which you put in the SIM card For testing this feature you can call another mobile phone there your phone number or name have to be displayed In case the STD35 e g due to being separated from the supply voltage the STD35 will send after the reapparition of the supply voltage automatically an SMS...

Page 5: ...signed mobile phone the relay 1 will switch for a second In case of a SMS O2ON The relay 2 will switch for a second The same is certainly valid as well for the outputs relay 3 to relay 5 In the case that the switching time has been put to 0 number 0 the relays switch permanently to the other status Configuration SMS The configuration SMS is valid only if beginning with the 4 digit password Teh CLI...

Page 6: ... numbers are entered in international format they have to start with a You can give authorization to up to one hundred of further phone numbers to switch the relay 1 by call To do so you have to build up the extended Clip list respectively you have to enter phone numbers into this Clip list You can also using CD erase again phone numbers within this list The texts for Event respectively Start up m...

Page 7: ...ol commands O1ON O2OFF O3ON Tracking via GPS By plugging of an appropriate GPS Mouse on the serial connector DSUB 9 of the front side of the STD35 you can transmit the GPS data directly to your mobile phone This function can be launched from the Admin respectively the 4 additional Masters durchgeführt werden The users who are in the extended Cliplist can Not use this function To ask for actual pos...

Page 8: ...s to be sent to the STD35 2759 BR x x 0 Baudrate 9600 Factory setting x 1 Baudrate 4800 Baud Modem Functionality of the STD35 For using the Modem functionality of the STD35 the serial interface has to be modified using a terminal program The STD35 is put to 9600 Baud 8N1 as the factory setting After connecting the RS232 with a terminal program on the PC just the simple command at has to be sent Th...

Page 9: ...nd EGSM 900 1800 MHz compatible with ETSI GSM Phase 2 Standard Output power Class 4 2W 900 MHz Class 1 1W 1800 MHz Temperature range 20 C 75 C Weight approx 160g Dimensions 130x85x30 mm LxBxH Supply voltage 5 32V DC Idle current 32 mA peak current up to 500 mA Max Switching current 5 A Max Switching voltage 30V AC Input voltage digital inputs logic 1 5 20V logic 0 1 5V I case of technical problems...