  When using components or modules it is necessary to strictly observe the specification given in the 

corresponding description of these components.  

  If a description for a private end-customer not clearly states which electric data is valid for a component or a 

module, how to wire the device, which external components or additional devices can be connected or which 

parameters these components are allowed to have, a specialist must be contacted.  

  Before putting a device into operation, it has to be clarified, whether this device or module is meant for the field 

of application. In case of doubt ask specialists or the manufacturer of the device.  

  Please note that we are not responsible for any errors in usage or connection. Therefore we cannot accept any 

responsibility for consequential loss.  

  Devices which operate with >35 Volt have to be connected by a specialist.  

  Before putting the device into operation it should be checked that there is no current leakage on the housing. 

  In case that measurements with the opened housing are necessary, an isolating-transformer has to be 

integrated for saftey reasons. Alternatively the voltage can be supplied by an appropriate power supply which 

complies with the safety regulations. All wiring work has to be done in a voltage free state only.  

Operating conditions 

  Operate the STD35 only with a supply voltage between 5-32V and have in mind the polarity! (see picture1) The 

power supply has to deliver at least 500mA. If you use a mains adapter for power supply it has to be conform 

with the VDE regulations.  

  Devices with an operating voltage >35 Volt have to be installed by a specialist observing the VDE regulations.  

  Loads connected to the device are not allowed to exceed 1000W per relay.  

  The maximum voltage is 250V AC (alternating current) 

  The maximum switching power per relay is 6A (depending on the width of the PCB tracks) 

  No special operation position of the device has to be observed. 

  When installing the device make sure that the supply cable has a sufficient diameter 

  During operation the temperature has to be between -20° and 55° Celsius.  

  In case of condensation allow a period of about 2 hours for acclimatisation.  

  Keep away the device from flower vases, bath tubs, washbasins, liquids etc.  

  The device is meant for operation in dry and clean rooms.  

  Protect the device from humidity, spray water and heat. 

  Do not expose the device to heavy vibrations. 

  Do not operate the device in areas where are or could be inflammable gas, vapours or dust.  

  The unit may only be repaired by a specialist. 

  Only original parts have to be used when repairing the unit. The use of differing spare parts can cause serious 

material loss or personal injury. 

Proper Use 

The device is designed for the remote switching of devices via the GSM network as well as the remote retrieval of 

status information of the inputs and the generation of SMS messages after status has changed at the inputs. A 

different utilisation of the device other than the one described above is not allowed.  

 

Introduction  

 

The STD35 is a telemetry module which is easy to install and simple to use. 

With the STD35 you can control five relays and monitor the status of five digital inputs with one or several common 

mobile phones. 

Apart from the STD35 you only need a valid SIM Card of any network provider (GSM 900 / 1800 MHz). 

While using prepaid SIM-cards one shall always keep himself aware of the amount left on the card, so that in case 

of alarms a SMS could be sent. 

Typical fields of application are the opening of (garage) doors, switching on and off light and alarm devices as well 

as generating alarm messages (SMS) or the retrieval of information from door sensors, movement sensors or level 

sensors etc. 

 

 

 

Summary of Contents for STD35

Page 1: ...cording to DIN VDE 0869 and obliged to hand out all necessary documents with the device and to indicate his name and address Devices which are made out of modules have to be considered as an industrial product from the safety perspective During use of the STD35 Short Messages SMS can be generated automatically Costs may occur for you by this SMS traffic Safety Instructions When using products whic...

Page 2: ...ltage is 250V AC alternating current The maximum switching power per relay is 6A depending on the width of the PCB tracks No special operation position of the device has to be observed When installing the device make sure that the supply cable has a sufficient diameter During operation the temperature has to be between 20 and 55 Celsius In case of condensation allow a period of about 2 hours for a...

Page 3: ...sed SIM card of a GSM network provider on which the PIN has been put to 0000 To change the PIN accordingly you can use a regular mobile phone Please get the proceeding for Pin change out of the corresponding user manual of your mobile phone In case of using a SIM card with another PIN than 0000 the STD35 will use a wrong PIN during each power on which leads to blocking of the SIM card after the 3r...

Page 4: ...private call has to be switched off This is a configuration that you can settle on your mobile phone in which you put in the SIM card For testing this feature you can call another mobile phone there your phone number or name have to be displayed In case the STD35 e g due to being separated from the supply voltage the STD35 will send after the reapparition of the supply voltage automatically an SMS...

Page 5: ...signed mobile phone the relay 1 will switch for a second In case of a SMS O2ON The relay 2 will switch for a second The same is certainly valid as well for the outputs relay 3 to relay 5 In the case that the switching time has been put to 0 number 0 the relays switch permanently to the other status Configuration SMS The configuration SMS is valid only if beginning with the 4 digit password Teh CLI...

Page 6: ... numbers are entered in international format they have to start with a You can give authorization to up to one hundred of further phone numbers to switch the relay 1 by call To do so you have to build up the extended Clip list respectively you have to enter phone numbers into this Clip list You can also using CD erase again phone numbers within this list The texts for Event respectively Start up m...

Page 7: ...ol commands O1ON O2OFF O3ON Tracking via GPS By plugging of an appropriate GPS Mouse on the serial connector DSUB 9 of the front side of the STD35 you can transmit the GPS data directly to your mobile phone This function can be launched from the Admin respectively the 4 additional Masters durchgeführt werden The users who are in the extended Cliplist can Not use this function To ask for actual pos...

Page 8: ...s to be sent to the STD35 2759 BR x x 0 Baudrate 9600 Factory setting x 1 Baudrate 4800 Baud Modem Functionality of the STD35 For using the Modem functionality of the STD35 the serial interface has to be modified using a terminal program The STD35 is put to 9600 Baud 8N1 as the factory setting After connecting the RS232 with a terminal program on the PC just the simple command at has to be sent Th...

Page 9: ...nd EGSM 900 1800 MHz compatible with ETSI GSM Phase 2 Standard Output power Class 4 2W 900 MHz Class 1 1W 1800 MHz Temperature range 20 C 75 C Weight approx 160g Dimensions 130x85x30 mm LxBxH Supply voltage 5 32V DC Idle current 32 mA peak current up to 500 mA Max Switching current 5 A Max Switching voltage 30V AC Input voltage digital inputs logic 1 5 20V logic 0 1 5V I case of technical problems...

Reviews: