background image

 

( 19 / 24 ) 

 

D4159008A

 

 

ex. 2) Video Start Line =256, Video Width=512 

(maximum speed on all pixel readout mode) 

 

 

 

 

 

 

 

 

 

 

FVAL

DATA OUT

LVAL

DVAL

A

B

C

D

A = approx. 1721.8us

B = approx. 25.5ms (512H-336CLK)

C = approx. 1586.7us

D = approx. 28.8ms

Video output:512 lines

Video start line:256

Valid lines:1024

Not read

Video width:512 lines

The rest of line:256

Not read

Video output

Summary of Contents for CSCS20BC2

Page 1: ...pecification CONTENTS Restriction For Use 2 Exemption Clauses 3 Notes on using this product 4 1 Overview 7 2 Features 7 3 Configuration 8 4 Option parts 8 5 Function 8 6 Specification 13 7 Timing Chart 17 8 Guarantee 22 9 Repair 22 10 External view Drawing 23 ...

Page 2: ...t designed or manufactured to be used for control of equipment directly concerned with human life 1 or equipment relating to maintenance of public services functions involving factors of safety 2 Therefore the product shall not be used for such applications 1 Equipment directly concerned with human life refer to Medical equipment such as life support systems equipment for operating theaters Exhaus...

Page 3: ...the operation manual and specifications TELI assumes no responsibility or liability in the case damages or losses are caused by use contrary to the instructions in this operation manual and specifications TELI assumes no responsibility or liability in the case damages or losses are caused by malfunction or other problems resulting from use of equipment or software that is not specified TELI assume...

Page 4: ... gain However such phenomena are not malfunctions Regarding a lens mount Install a next lens the C mount lens its dimension of protrusion from flange is equal to or less than 7 9 mm If a lens does not stand to this condition it might not be installed to this camera Check a combination with the lens Depending on the lens and lighting you use an image is reflected as a ghost in the imaging area Howe...

Page 5: ...ccurrence of noise on the screen If an intense magnetic or electromagnetic field is generated near the camera or connection cable noise may be generated on the screen If this occurs move the camera or the cable Handling of the protective cap If the camera is not in use attach the lens cap to the camera to protect the image pickup surface If the equipment is not to be used for a long duration Turn ...

Page 6: ...should be separated and discarded in compliance with the various national and local ordinances This camera is showing the following symbol to body due to EU environmental regulation Waste Electrical and Electronic Equipment WEEE However this symbol is applied to only a EU member state ...

Page 7: ... 4 Camera Link interface power supply type By using a Camera Link capable frame grabber board to which power can be supplied high speed transfer of captured images to a PC as well as various types of camera control from the PC are allowed Power can also be supplied to the camera with only one cable 5 Random trigger shutter function CSCS20BC2 is equipped with a random trigger shutter which starts e...

Page 8: ...interface it is possible to control the following functions 1 Set up Addition Value 10bit 0 to 255 digit 8bit 0 to 63 digit 2 Gain 0dB to Approx 12dB 3 Shutter Speed 2 sec to 1 20 000 sec 4 Random Trigger Shutter ON OFF Restart Reset mode must be disabled Trigger VD Polarity Positive Negative Random Trigger Mode Fix Pulse Width 5 Restart Reset ON OFF Random Trigger Shutter mode must be disabled 6 ...

Page 9: ...ess max length is 2 bytes and Data s max length is 8 bytes For example to write data 0x38 to address 0x76 send a command as follows The camera responds to the write command with No Error ACK or Error NAK as follows No Error ACK Error NAK Because two kinds of data is needed for the setting about the Partial Scan the register writing for Set value application is separately needed Address 2nd byte Ad...

Page 10: ...esponds to the read request as follows Data s max length is 8 bytes Actually the camera responds to the read request as minimum data length For example to read data 0x10 to address 0x91 the camera responds as follows 9 0x39 1 0x31 0x2C R 0x52 Q 0x51 CR 0x0D Data 8thby te Data 7thby te Data 6thby te Data 5thby te Data 4thby te Data 2ndby te Data 1stby te CR 0x0D Data 3rdby te 1 0x31 0 0x30 CR 0x0D ...

Page 11: ...SCII Format CPLD1 Version ASCII Format Register Map Version ASCII Format Status Expanded Status Reserved Memory Bank Confirmation Save to Memory Load from Memory Initialize Memory Setup Offset Addition Value Reserved Reserved Gain Reserved Reserved FPGA Version ex 01 01 01 CPLD1 Version ex 01 01 01 Register Map Version ex 01 01 Status Status information after Camera Controlling Expanded Status Det...

Page 12: ...erator Reserved Reserved Shutter Speed denominator Reserved Reserved Trigger Polarity Random Trigger Shutter Mode Shutter Mode Scan Mode Reserved Reserved Output Bit Reserved Vertical Resolution Horizontal Resolution Frame Rate Horizontal Resolution 1360 fixed Vertical Resolution 1024 Normal Scan Video Width Partial Scan Default 1024 Normal Scan Output Bit 8 8bit 10 10bit Default 8 8bit Scan Mode ...

Page 13: ... factory default 1360 H 1024 V Approx 19 5fps Partial Scan ex 1 1360 H 768 V Approx 25 0fps ex 2 1360 H 512 V Approx 34 8fps minimum lines 6512 minimum step 1 line 6 Sensitivity 500 lx F5 6 7 Minimum subject illuminance 5lx F1 4 GAIN 10dB video level 50 8 Gain 0 to Approx 12 dB 1step Approx 0 132dB 9 Setup Level factory default 40 20 digit 10bit 10 5 digit 8bit addition value 0 to 255 digit 10bit ...

Page 14: ... in the pickup device or CCD Camera itself 2 Random Trigger Shutter ON OFF switching factory default OFF Fixed mode The exposure time depends on the shutter speed setting pulse width mode The exposure time depends on the pulse width 3 Restart Reset ON OFF switching factory default OFF The exposure time depends on the period of Ext VD Input signal specification 1 TRIG VD Camera Link interface input...

Page 15: ...dy grounding insulation status Conductive between circuit GND and camera body Operating ambient conditions 1 Performance assurance Temperature 0 C to 40 C Humidity 10 to 90 no condensation 2 Operation guaranteed Temperature 5 C to 45 C Humidity 90 or less no condensation 3 Storage Temperature 20 C to 60 C Humidity 95 or less no condensation 4 EMC conditions Electro Magnetic Compatibility EMI Elect...

Page 16: ...OUT0 3 O TxOUT1 16 O TxOUT1 4 O TxOUT2 17 O TxOUT2 5 O TxCLK OUT 18 O TxCLK OUT 6 O TxOUT3 19 O TxOUT3 7 I SerTC RxD 20 I SerTC RxD 8 O SerTFG TxD 21 O SerTFG TxD 9 I CC1 TRIG VD 22 I CC1 TRIG VD 10 I CC2 23 I CC2 11 I CC3 24 I CC3 12 I CC4 25 I CC4 13 GND 26 12V Please confirm the power supply of the camera cuts when the connector is connected or pulls out It causes the breakdown etc Typical ambi...

Page 17: ...you have to change the shutter speed to 1 19 5s or shorter LVAL DVAL b DATA OUT a 336CLK b 22CLK c 16CLK d 1360CLK f 40CLK c e 16CLK d e f FVAL Same timing FVAL DATA OUT LVAL DVAL A B B approx 50 9ms 1024H 336CLK Vertical Timing maximum speed on all pixel readout mode Horizontal Timing C 1frame A B C approx 51 3ms 1H 1790CLK A approx 271 1us a C approx 136 0us ...

Page 18: ...eo Start Line 128 Video Width 768 maximum speed on all pixel readout mode FVAL DATA OUT LVAL DVAL A B C A approx 996 4us B approx 38 2ms 768H 336CLK C approx 861 3us D approx 40 0ms D Video output 768 lines Video start line 128 Not read Video width 768 lines The rest of line 128 Not read Video output Valid lines 1024 ...

Page 19: ... on all pixel readout mode FVAL DATA OUT LVAL DVAL A B C D A approx 1721 8us B approx 25 5ms 512H 336CLK C approx 1586 7us D approx 28 8ms Video output 512 lines Video start line 256 Valid lines 1024 Not read Video width 512 lines The rest of line 256 Not read Video output ...

Page 20: ...e camera link I F CC1 If polarity is set to negative polarity exposure starts at the falling edge of the trigger The random trigger shutter of this camera can be operated in two types of mode fixed mode and pulse width mode How to determine the exposure time differs depending on the mode z Fix mode The exposure time is determined by the setting value for the shutter speed Pulse Width mode Trigger ...

Page 21: ...ently with the Random Trigger Shutter mode External VD signals can be input either from the camera link I F CC1 The shutter speed exposure time is determined by ext VD signal interval The image is outputted behind time for a maximum of 1 0H from an external VD signal 1 Vertical Timing CCD exposure DATA OUT FVAL VD 2 Horizontal Timing DATAOUT CCD exposure Ext VD input FVAL more than1H when the exte...

Page 22: ...s and damages by transportation 3 Troubles and damages by fire natural calamity earthquake storm and flood damage thunderbolt damages from salty breeze gas harm abnormal voltage 9 Repair 9 1 Condition for repair Basically has to return it to our company when the user requests us to repair product Beside that customer should pay these expenses travel expenses camera disassembly technology costs of ...

Page 23: ... 23 24 D4159008A 10 External view Drawing ...

Page 24: ...e 7 1 4 chome Asahigaoka Hino shi Tokyo 191 0065 Japan Overseas Sales Department Phone 81 42 589 8771 Fax 81 42 589 8774 URL http www toshiba teli co jp The design and specification is subject to change without notice Distributer ...

Reviews: