20
Full
Full lock prevents access to all controls. After Full Lock has been set, the only action possible is to
press the Unlock key and type in a password. If the correct password is typed in, the Full Lock is
defeated.
To set Full Lock:
1. Type in the desired password of up to 8 letters, using the frequency keys.
2. The procedure can be aborted by pressing the Exit key.
3. Press the Full key.
Partial
Partial lock prevents access to all controls except for Memory Recall. After Partial Lock has been set,
the only action possible is to Recall a memory (press the Recall key) or unlock the unit by pressing the
Unlock key and typing in the correct password. If the correct password is typed in, the Partial Lock
is defeated.
To set Partial Lock:
1. Type in the desired password of up to 8 letters, using the frequency keys.
2. The procedure can be aborted by pressing the Exit key.
3. Press the Partial key.
Exit
Soft key 4 is accompanied by the text Exit. Pressing this key returns the unit to the start-up menu.
More. . . Utilities menu
Accessed by pressing the Utilities key followed by the More. . . key.
Soft key options: Slaves
MIDI Chan
Inv LCD
Exit
Slaves
Soft key 1 is accompanied by the text Slaves. Pressing this key enables the selection of Slave
devices to be addressed. Pressing this key also causes the DN3600 to assume the roll of Master
over any connected DN3600/DN3601 units. Use the FREQ or LEVEL rotary control to cycle
through the various options:
STAND ALONE
The normal mode of operation. All controls and adjustments affect only the one, local DN3600 unit.
The DN3600 must always be returned to STAND ALONE mode in order to control itself.
ALL
All controls and adjustments affect all the compatible slave devices connected into the network,
including the local, Master DN3600 unit.