19
Memory/Lockout menu
Accessed by pressing the Utilities key followed by the Memory key.
Soft key options: Recall
Save
Lock
Exit
Recall
Soft key 1 is accompanied by the text Recall. This key allows any of the 66 named memories to be
recalled. To recall a memory:
1. Press the Recall key once.
2. The NUMBER window shows the selected memory number while the LCD shows the
memory name and fader positions. Select the required memory by name and/or number by use
of the FREQ or LEVEL rotary control.
3. The procedure may be aborted at any time by pressing the Exit, Lock or Save keys.
4. Press the Recall key once more. At this point all the fader, filter, Q and Gain settings are
updated.
The current memory name is shown as text at the top of the screen. The current memory number is
shown in the NUMBER window unless any manual changes are made.
Save
Soft key 2 is accompanied by the text Save. This key allows the current equaliser settings to be stored
in any of the 66 memory locations. Each memory may be given an 8 character name. To Save a memory:
1. Press the Save key once.
2. Select the memory number by use of the FREQ or LEVEL rotary control. Memory number is
shown in the NUMBER window. Memory name - if any - is shown on the LCD.
3. If desired, enter a new memory name or edit the old memory name using the Frequency keys.
These correspond to the letters A to Z. By pressing the SHIFT key, the numbers 0 to 9 may
also be accessed. The < key is a backspace or delete function.
4. The procedure may be aborted at any time by pressing the Exit, Lock or Recall keys.
5. Press the Save key a second time.
All fader, filter, Q and gain data for both channels is saved in a memory. The current memory name is
shown as text at the top of the screen.
Lock
Soft key 3 is accompanied by the text Lock. This key allows access to the two lock modes. When
the key is pressed, the menu options change to:
Full
Partial
Exit