Televes 593581 Instruction Manual Download Page 31

EN

31

Error Messages

LOW BATTERY

Indicates that the battery is about to finish. The 

battery icon is red now. It is recommended to 

connect the meter to the external power source.

LOW BATTERY

Shutting down

Some time after the LOW BATTERY message 

appears (time varies depending on the functions 

used), it will appear this message. If the meter is 

not connected to the external power source, it will 

switch off.

BAD POWER

Unplug power source

This message appears when the meter is 

connected to an external power source that does 

not supply it the right power. Please, use only the 

power source provided with the 

H30Evolution

.

SHORT-CIRCUIT

Check installation

This message appears when the meter detects a 

short-circuit at the RF input. It is recommended to 

check the installation to find out why the short-

circuit is produced.

DC OUTPUT LIMIT EXCEED

Switch DC OUTPUT off

This message appears when the meter detects 

an excessive consumption from the device that is 

being powered. It is recommended to turn off the 

powering feature of the 

H30Evolution.

DC AT RF INPUT

Check installation

This message appears when the meter detects 

DC at the RF input that is not generated by the 

H30Evolution

. It is recommended to check the 

installation.

Maintenance

Always disconnect the unit before cleaning. Use 

only a mild solution of detergent and water applied 

with a soft damp cloth. Dry thoroughly before use.
Do not use aromatic hydrocarbons or chlorinated 

solvents. These products may damage the unit.
Do not use alcohol or alcohol based products 

on the front panel, especially the display. These 

products may damage the unit.

Summary of Contents for 593581

Page 1: ...EN Instruction Manual ATSC Meter Analyser with digital processing Ref 593581 593585 ...

Page 2: ......

Page 3: ... Echoes only for ATSC3 0 14 8 Wi Fi Scan 15 9 IPTV 16 10 Setup 18 Firmware Update 20 Web Application 20 1 Measurements 20 2 Plans 21 3 Quality Profiles 22 4 Screen Mirroring 22 5 Clone 23 6 Update 23 Mobile Devices App 24 1 Connection between the App and the H30Evolution 24 2 Features 25 2 1 Loggers 25 2 2 Multiscreen 25 2 3 Files 26 2 3 1 Channel Plans 26 2 3 2 SCR 28 2 3 3 Quality Profile 28 2 3...

Page 4: ...ce personnel Follow the instructions in this manual when replacing the battery Heat The product should be situated away from heat sources such as radiators heat registers stoves or other products that produce heat Do not place naked flame sources on the meter such as lighted candles Maximum current consumed by the meter 2A Battery Battery must be replaced by qualified personnel following the steps...

Page 5: ...ements needed in today s fulfilment environment Key Features User friendly handheld TV meter Complete portfolio of Analog Digital measurements with easy to read pass fail indicators Quick and easy to use interface with features such as Channel measurements System Scans Constellation Diagram Spectrum Analyzer Echoes Datalogger and more Rugged light weight fully automatic fast and accurate Easy upda...

Page 6: ...z Output 12VDC 2A Battery Li Ion smart battery 7 2VDC 2300mAh Operating Time Up to 4 hours Operating Temperature 23ºF to 104ºF 5ºC to 45ºC Storage Temperature 4ºF to 158ºF 20ºC to 70ºC Humidity 5 to 95 non condensing Ruggedness Survives 1 m 3 ft drop to concrete on all sides Communication Interfaces USB 2 0 to download Datalogs and software updates Storage 400 MB internal for measurements Power up...

Page 7: ... Digital Measurements ATSC 1 0 Freq Range 42 1002MHz Video Modulation 8VSB Power 15 50dBmV 35 60dBmV opt 593235 MER Up to 38dB PreBER 9 9E 2 1 0E 6 PostBER 1 0E 3 1 0E 8 Constellation Digital Measurements QAM Freq Range 42 1002MHz Video Modulations 64QAM and 256QAM Power 15 50dBmV 35 60dBmV opt 593235 Pre BER and Post BER 1 0E 3 1 0E 8 MER Up to 38dB C N Up to 40dB Constellation Analog Measurement...

Page 8: ...hold for approximately 3 seconds 2 Back button Return to the previous menuorcloseaparameterentrywindow 3 Home button Return to the main menu 4 Navigation buttons Used to scroll through options 5 OK Button To confirm selection 6 Setup button Parameter window for the current function 7 LED Powering Indicates if the equipment is powering an external load 8 LED Charging Battery LED flashes while the b...

Page 9: ...ge greater than 75 From a fully discharged state a full charge takes approximately 4 hours and a 2 hour charge will provide approximately a 75 charge The charge management system will detect various conditions preventing charging such as a battery that is over a safe temperature About battery Important If the meter detects a shortcircuit or over consumption and it is not connected to the power sup...

Page 10: ...hannel plan Powering Selects the preamplifier powering Tuning Channel Frequency A D Auto Analog Digital Save datalog Saves the current channel measurements You can see the datalogs using the remote control application 2 Spectrum Real time processing speeds ensure capture of any fast intermittent plant impairments Due to the accuracy and level of detail provided by this spectrum analyzer the H30Evo...

Page 11: ...et the reference level manually as well as to select the span to include a frequency range wide enough The audible signal becomes continuous when the signal leves is close to the reference level Then it is necessary to increase the reference level to get a more accurate adjustment This is a useful feature to point antennas without having to look at the display Span 5MHz 10MHz20MHz 50MHz 100MHz 200...

Page 12: ...the selected channel with pass fail indicators Channel Change using Frequency 4 2 Setup Press to change the System Scan options Ter Plan Selects the channel plan Powering Selects the preamplifier powering Digital tuning If it is ON allows to see MER and CBER measurements when a digital channel is selected and the user presses Ok button Span Select the number of channels showed in the bar graph Ref...

Page 13: ...stellation diagrams are an indispensable tool to help detect the presence of noise phase jitter interference and gain compression all of which impact overall signal quality and thus reduce Modulation Error Ratio MER Ideally each of the symbols in a constellation diagram should display a clean dot indicating a perfect signal The H30Evolution s real time constellation allows theinstallertoassessthes...

Page 14: ...the reception of ATSC3 0 signals This feature allows you to visualize the echoes of the received signal helping the installer to minimize them as much as possible for optimal signal reception In addition to the echoes graph this function shows the channel power and MER measurements as well as the FFT mode the guard interval and the Cell ID 7 1 Main window Below is a capture of a Ecos window with a...

Page 15: ...i Fi networks as well as their names and the power of the access point signal There are two different screens to display the information List and Map 8 1 List view You can go through the list using and select one of the Wi Fi networks to display it separately If a Wi Fi network has multiple access points you will see several networks with the same name If you select one of them you will separately...

Page 16: ...ation of its feature 9 1 1 2 Setup Press to change IPTV Measurements options List of measurements Selected channel data Selected channel Channels Allows to change the selected IPTV channel Save Datalog Saves the current IPTV measurements You can see the datalogs using the remote control application 9 1 2 MPEG Using this function you can see the Video 9 1 2 1 Main Window Below is a capture of a IPT...

Page 17: ... channel services 9 1 3 1 Main Window Below is a capture of a IPTV Services window with a brief explanation of its feature Once you have selected a service press OK to see all the parameters and bitrates of the audio and video List of services and bitrates Press to select a service Selected channel parameters Selected channel Video ID Video Type and bitrate Audio ID Audio Type bitrate and language...

Page 18: ...HRC FCC OFFAIR CCIR and customers plans Restore Powering On Off Language English Español Units dBµV dBmV dBm Quality profiles Trunk Tap End Line Ground Differentthresholdsareavailablefordifferent testing locations Analog Standard Selects the standard for the analog channels and changes automatically the audio carrier to a value according to the selected standard Audio Carrier 4 5 MHz 5 5 MHz 6 0 M...

Page 19: ...nual is selected the user must enter the MAC using and SSID Shows the SSID of the H30Evolution BSSID Shows the SSID of the H30Evolution IP Shows the SSID of the H30Evolution Bluetooth Allows to turn ON OFF the bluetooth connection If ON is selected it will appear a new line showing the MAC of the H30Evolution Bluetooth interface and a bluettoth icon will be shown in the top right part of the scree...

Page 20: ...all the new firmware version The icon with the arrow indicates that there is a new firmware version Web Application First of all connect your H30Evolution to the network using the Ethernet connector or the Wi Fi interface Then you must find out the IP of your H30Evolution see section 11 Setup Network Wi Fi Then type your H30Evolution IP in the address bar of your web browser and press Enter Then y...

Page 21: ...nts Filter according to channel type 2 Plans In this window you can see all the channel plans of your H30Evolution They are grouped in three categories Terrestrial Satellite and Customer The Terrestrial and Satellite channel plan are the standard channel plans of the corresponding band These plans can be removed from the meter but they can not be edited However you can make a copy of one of them t...

Page 22: ...H30Evolution in Duplicate profile you can start from scratch by clicking on the New custom plan button The application also allows to configure the channel plans according to the geographic area you will use the meter When you turn the meter on for the first time you must select the language and then you must select the geographic area So the channel plans corresponding to that area will be availa...

Page 23: ...nstall them automatically But if you get the licenses from your distributor you can install them in your device by clicking on Add license your computer 5 Clone Using this feature it is very easy to have the same configuration in all your H30Evolution meters You only have to export the configuration of the H30Evolution that you wanto to copy using the Ex port feature So the configuration will be s...

Page 24: ...ttings function of your mobile device and turn Wi Fi ON and make sure that your H30Evolution Wi Fi is present at the networks list the name of the Wi Fi is H30Evolution followed by the serial number 3 Select to connect to your H30Evolution Wi Wi Fi name and connection key are shown Turn your mobile device Wi Fi ON Fi Your mobile device will ask for the key that is Televes1 4 Then open the H30Evolu...

Page 25: ... on one of these logs to select it you will see all the measurements at the bottom of the screen Tap to select a DataLog When you tap on logger the measurements in that logger will be shown 2 2 Multiscreen Using this feature you can use your iPad to control remotely your H30Evolution Note in the current version it is not possible to run the Wi Fi Scan function using the Multiscreen fea ture When y...

Page 26: ...it full screen Note1 HEVC videos can only be displayed on ta blets that support this standard but will not be displayed on the H30Evolution Note2 4K videos are not supported on the tablet or H30Evolution Note3 If the user selects theVideo Camera function while using the multiscreen feature the image will not be displayed in real time 2 3 Files This feature allows to manage channels plans SCR files...

Page 27: ... channel plans list User defined Plans Standard Plans Clone channel plan Enter the new user defined channel plan name and it will be automatically uploaded to your H30Evolution The channel plans in the user list can be edited Type the new channel plan name and tap on Save Add new channel Save changes To edit a channel tap on the corresponding cell ...

Page 28: ...ution and points directly to the Quality Profile section See section 4 Quality Profiles of the Web Application 2 3 4 IPTV With this function the user can create and edit IPTV channel plans Each plan has only one channel indicating the IP address and the port for When the Delete button is visible tap it to delete the channel each channel To add a new IPTV plan it is necessary to duplicate an existi...

Page 29: ... will ask you to register it If you register your H30Evolution within 30 days you will get two options valued in 200 for free If you press BACK you can use your H30Evolution If you press OK it will begin the registration process The user can choose to use his her mobile phone to read the QR code or use the Register function of the H30Evolution App note the mobile device wich the app is running on ...

Page 30: ...ser with the Televes Meter Registration web page Register your H30Evolution in our web Once the process is completed you will get a PIN code by email Enter the PIN code in your H30Evolution 2 4 4 Clone Using this feature it is very easy to have the same configuration in all your H30Evolution meters You only have to export the configuration of the H30Evolution that you wanto to copy using the Ex po...

Page 31: ...t circuit at the RF input It is recommended to check the installation to find out why the short circuit is produced DC OUTPUT LIMIT EXCEED Switch DC OUTPUT off This message appears when the meter detects an excessive consumption from the device that is being powered It is recommended to turn off the powering feature of the H30Evolution DC AT RF INPUT Check installation This message appears when th...

Page 32: ... a new or factory reconditioned equivalent or refund the purchase price of the Product s that has been determined by Televes to be defective in material or workmanship subject to the limits of this warranty C This warranty excludes any inoperability resulting from I use or installation that is not in strict compliance with the written instructions and specifications II any modification or alterati...

Page 33: ...le discretion without notification No other warrantees are expressed or implied Supplier s Declaration of Conformity Compliance with standards Responsible Party U S Contact Information Televes USA Norfolk Tech Center 16596 E 2nd Avenue Aurora CO 80011 Telephone 1 720 379 3748 televes usa televes com FCC Compliance Statement Contains FCC ID Z64 WL18DBMOD This device has been tested and found to com...

Page 34: ...Cet appareil numérique de la classe A est conforme à la norme CAN ICES 003 A NMB 003 A du Canada Le présent appareil est conforme aux CNR d ISDE applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 L appareil ne doit pas produire de brouillage et 2 L utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le br...

Page 35: ......

Page 36: ......

Page 37: ...593581_593585_1 02_EN ...