Telesis FQ20 Manual Download Page 5

 
 

FQ20 Laser Marking System

 

 

 

System PC 

The laser system requires an IBM-compatible computer for 
running the Merlin

 

II LS Laser Marking Software. The PC may be 

a desktop or a notebook computer and may be supplied by Telesis 
or by the customer. If the PC is supplied by Telesis, warranty for 
the computer, computer keyboard, monitor, and peripherals 
default to the original equipment manufacturer. 

Galvo control cards are included, along with interconnect cabling. 
The laser software is installed and the entire unit is tested as a 
laser marking system. 

The minimum computer requirements are as follows: 

 

Windows

®

 

2000, Windows

®

 

XP or Windows

®

 

Vista

™ 

Business 

 

Telesis Merlin II LS Laser Marking Software 

 

Pentium

®

 

III with recommended RAM as per operating system 

 

Multi-gigabyte, HDD 

 

CD-ROM and 3.5 in. External Disk Drives 

 

SVGA Color Monitor, Mouse, and Keyboard 

 

Laser/Galvo Controller Board 
(configured for stationary marking or marking “on-the-fly”) 

 

Video Card 

 

One available RS-232 Serial Port 

 

Two available USB Ports 

 

Three (minimum) full-height PCI Slots * 

Note: 

If a notebook computer is used, expansion  
must be used to provide the PCI slots. 

 

System Software 

The powerful Telesis Merlin II LS Laser Marking Software is a 
Windows

®

 

based operating software package that comes standard 

with the laser marking system. It is a graphical user interface that 
makes marking pattern design quick and easy. The WYSIWYG 
(what-you-see-is-what-you-get) interface provides a to-scale 
image of the pattern as it is created. Just “click and drag” for 
immediate adjustment to field size, location, or orientation. 

 

The Merlin

 

II LS includes tools to create and edit text (at any 

angle), arc text, rectangles, circles, ellipses, and lines. Multiple 
fields may be grouped and saved as a block to form a logo. 
Existing DXF files can also be imported for marking. Non-
printable fields can be created to clearly display a graphical 
representation of the part being marked.  
 
 

 

Overview of Merlin II LS User Interface 

 
 

Merlin

 

II LS Laser Marking Software Specifications 

Operating System ..................Windows

®

 

2000, Windows

®

 

XP, or 

Windows

®

 

Vista

™ 

Business

 

using a 

Desktop PC or Notebook PC 

Font Generation.....................True Type Fonts 

Barcodes and Matrix .............2D Data Matrix, PDF417, BC 39, 

Interleaved 2 of 5, UPCA/UPCE BC 
128, Maxi Code, Code 93, QR Code 
and others 

Graphic Formats ....................Raster and Vector: BMP, GIF, JPG, 

WMF, EMF, CUR, ICO, DXF 

Serialization...........................Automatic and Manual Input 

Host Interface Capable 

Linear Marking......................Scalable with Letter Spacing 

Control 

Arc Text Marking..................Scalable and Adjustable 

Drawing Tools.......................Line, Rectangle, Circle, Ellipse 
 
 

 

Doc No. 47773 Rev. E 

5 of 7 

Summary of Contents for FQ20

Page 1: ...vailable in two configurations One is capable of marking only stationary objects The other is capable of marking objects while they are moving i e mark on the fly operation The basic lasersystem consi...

Page 2: ...unting position taking care not to bend or kink the fiber optic cable The fiber optic cable will take an approximately 12 in 305 mm diameter bend without damage 5 Mount the laser marking head by using...

Page 3: ...6 in 330mm 177 622 mm 6 993 in 350mm 159 106 mm 6 264 in 420mm 177 622 mm 6 993 in Mounting Weight approx 6 82 Kg 15 lbs Mounting Holes four factory tapped M6 1 00 Aiming visible red diode beam Field...

Page 4: ...Laser Controller Specifications Dimensions W x H x D 425 5 x 144 3 x 508 0 mm 16 75 x 5 68 x 20 00 in Surrounding Envelope 628 7 x 152 5 x 762 0 mm 24 75 x 6 00 x 30 00 in Weight approx 15 Kg 33 lbs...

Page 5: ...arking Software is a Windows based operating software package that comes standard with the laser marking system It is a graphical user interface that makes marking pattern design quick and easy The WY...

Page 6: ...be taken into account when installing the auxiliary controller concerning contaminants and EMI susceptibility For details refer to the Installation Maintenance Manual supplied with the controller Com...

Page 7: ...ype V can provide data to a variable text string in the pattern or poll the pattern for data P Message Type P can load a pattern or poll the system for the current pattern name O Message Type O places...

Reviews: