Telesis FQ20 Manual Download Page 2

 
 

FQ20 Laser Marking System

 

 

 

 

 

FQ20 Laser Marking Head Dimensions and Mounting Details 

 

System Setup 

Complete installation procedures are provided in the 

FQ20 

Installation/Maintenance Manual

. The following procedures are 

listed for reference only to provide a general overview of the 
installation process. 

Note:

 A minimum distance of 8 in. (204 mm) should be allowed 

at the rear of the laser controller to allow for a proper bend radius 
of the fiber optic cable. A minimum of 4 in. (102 mm) should be 
allowed on each side of the controller to permit proper air flow. 

Do not block the vented openings on the laser controller.

 

Note:

 A minimum distance of 8 in. (204 mm) should be allowed 

around the laser marking head. This permits proper air circulation 
and allows room for a proper bend radius of the fiber optic cable. 

1. 

Equipment should remain powered down and in the 

OFF

 

position until the mounting is complete.  

2. 

Place the computer, monitor keyboard in the desired location.  

3. 

Place the controller as close as practical to the laser marking 

head. The standard cable length is 5 meters (16 feet). 

4. 

Place the laser marking head onto the mounting position 
taking care not to bend or kink the fiber optic cable. The 
fiber optic cable will take an approximately 12 in. (305 mm) 
diameter bend without damage. 

 

5. 

Mount the laser marking head by using four M6-1.0 bolts. 
Torque to 80 in-lb (9.04 N-m). 

a. 

Mounting holes are tapped for metric threads. The 
mounting pattern is a four (4) hole rectangular pattern 
2.0 in. wide by 3.75 in. long (50.8 x 95.25 mm). The 
holes are tapped 0.30 in. (7.62 mm) deep for M6-1.00 
bolts.  

Mounting bolts must not extend into the 

laser marking head as to interfere with the 
internal components.

  

b. 

The leading edge of the mounting plate must not 
extend more than .375 in. (9.5 mm) forward of the 
first set of holes to allow clearance for the beam 
output lens.  

c. 

As viewed from the back of the laser marking head, 
the center of the output beam is 3.125 in. (79.375mm) 
forward of the first set of mounting holes and 
0.732 in. (18.593 mm) inward from the left side set of 
mounting holes.  

6. 

Ensure laser controller power switch (on front panel) is 

OFF

.  

7. 

Select proper fuse arrangement, then connect power cable. 

8. 

Connect the remaining cables. 

9. 

Refer to the 

FQ20 Operation Supplement

 for proper startup 

procedure of the complete system. 

10. 

Refer to the 

Merlin II LS Operating Instructions 

for 

complete information on using the system software. 

 

Doc No. 47773 Rev. E 

2 of 7 

Summary of Contents for FQ20

Page 1: ...vailable in two configurations One is capable of marking only stationary objects The other is capable of marking objects while they are moving i e mark on the fly operation The basic lasersystem consi...

Page 2: ...unting position taking care not to bend or kink the fiber optic cable The fiber optic cable will take an approximately 12 in 305 mm diameter bend without damage 5 Mount the laser marking head by using...

Page 3: ...6 in 330mm 177 622 mm 6 993 in 350mm 159 106 mm 6 264 in 420mm 177 622 mm 6 993 in Mounting Weight approx 6 82 Kg 15 lbs Mounting Holes four factory tapped M6 1 00 Aiming visible red diode beam Field...

Page 4: ...Laser Controller Specifications Dimensions W x H x D 425 5 x 144 3 x 508 0 mm 16 75 x 5 68 x 20 00 in Surrounding Envelope 628 7 x 152 5 x 762 0 mm 24 75 x 6 00 x 30 00 in Weight approx 15 Kg 33 lbs...

Page 5: ...arking Software is a Windows based operating software package that comes standard with the laser marking system It is a graphical user interface that makes marking pattern design quick and easy The WY...

Page 6: ...be taken into account when installing the auxiliary controller concerning contaminants and EMI susceptibility For details refer to the Installation Maintenance Manual supplied with the controller Com...

Page 7: ...ype V can provide data to a variable text string in the pattern or poll the pattern for data P Message Type P can load a pattern or poll the system for the current pattern name O Message Type O places...

Reviews: