FQ20 Laser Marking System

 

 

 

 

Doc No. 47773 Rev. E 

3 of 7 

System Specifications 

Compliance............................ CDRH, CSA 

Laser Type ............................. Q-switched Ytterbium fiber 

Wavelength............................ 1060 nanometers (±10 nm) 

CW Average Power  .............. 20 watts 

Expected Diode Lifetime ....... >50,000 hours 

Long Term Output  
   Power Drift ......................... ± 5% 

 

The laser marking head produces a visible red diode that may be 
viewed on the work surface without the need for protective safety 
goggles. This provides a safe and convenient aid for laser setup 
and part programming. Since the red beam is located 

after

 the 

shutter, the aiming beam may be used with the shutter opened or 
closed. Additionally, the visible red beam may be used with the 
lasing beam 

Avg. Power Consumption...... < 500 watts 

Input Power ........................... 95 to 250 VAC 50/60 Hz 

Supply Voltage Fluctuation ... ± 10%, maximum; clean ground line 

Oper. Temperature................. 18° to 35°C (65° to 95°F) 

Recommended Temp. ............ 20° to 25°C (68° to 77°F) 

Oper. Relative Humidity........ 10% to 85%, non-condensing 

 

 

Laser Marking Head  

The laser marking head includes the shutter assembly, visible red 
aiming diode, circuit board, galvanometer assembly, and the flat-
field lens. The beam collimator and isolator (at the end of the fiber 
optic cable) are enclosed within the laser marking head. 

Laser Marking Head Specifications 

Dimensions (L x W) .............. 510.464 x 127.000 mm  

 (20.097 x 5.000 in.) 

Dimensions (H)...................... Dependent on lens selection: 

100mm:  144.120 mm (5.674 in.) 
160mm:  142.113 mm (5.595 in.) 
163mm:  158.115 mm (6.225 in.) 
254mm:  172.110 mm (6.776 in.) 
330mm:  177.622 mm (6.993 in.) 
350mm:  159.106 mm (6.264 in.) 
420mm:  177.622 mm (6.993 in.) 

Mounting  Weight.................. approx. 6.82 Kg (15 lbs.) 

Mounting Holes ..................... four factory-tapped M6-1.00 

Aiming................................... visible red diode beam 

Field Resolution..................... 16 bit (65535 data points) 

Galvanometer Repeatability .. less than 22 micro radian 

Marking Field Size  ............... lens-dependent, see chart 

Fiber-Optic Cable Length ...... 3 m (9.8 ft.) 

Umbilical Cable Length......... 5 m (16.4 ft.), detachable 

Laser Ext. Cable Length ........ 3.05 m (10.0 ft.), detachable 

 

Marking Field Size 

The size of the marking field is dependent on lens type.  
See 

Flat-Field Lens

Visible Red Aiming Diode 

during the marking cycle. Note that protective 

eyewear must always be worn when the laser is in operation. 

Flat-Field Lens  

The flat-field lens is key to the marking performance of the 
system. This is the final coated optical lens that the beam will pass 
through before it strikes the marking target. This lens is called a 
flat field lens because when the beam is focused, the focus lies in a 
plane perpendicular to the optical axis of the lens. To protect the 
lens from dust and debris, a clear protective cover is inserted 
between the work area and the lens.  
 
The following chart outlines the available lenses, the resulting 
image field provided by the lens, and the working clearance (in 
millimeters and inches). 
 
 

Lens

 

Image Field 

 

(mm) (in.) 

Working 

Clearance 

 (mm)  (in.)

 

100 mm

65 x 65 

2.56 x 2.56 

98 

3.86 

160 mm

90 x 90 

3.54 x 3.54 

176 

6.93 

163 mm

110 x 110 

4.33 x 4.33 

185 

7.28 

254 mm

175 x 175 

6.89 x 6.89 

296 

11.65

330 mm

230 x 230 

9.06 x 9.06 

387 

15.24

350 mm

250 x 250 

9.84 x 9.84 

391 

15.39

420 mm

290 x 290 

11.42 x 11.42 

493 

19.41

 
 

Summary of Contents for FQ20

Page 1: ...vailable in two configurations One is capable of marking only stationary objects The other is capable of marking objects while they are moving i e mark on the fly operation The basic lasersystem consi...

Page 2: ...unting position taking care not to bend or kink the fiber optic cable The fiber optic cable will take an approximately 12 in 305 mm diameter bend without damage 5 Mount the laser marking head by using...

Page 3: ...6 in 330mm 177 622 mm 6 993 in 350mm 159 106 mm 6 264 in 420mm 177 622 mm 6 993 in Mounting Weight approx 6 82 Kg 15 lbs Mounting Holes four factory tapped M6 1 00 Aiming visible red diode beam Field...

Page 4: ...Laser Controller Specifications Dimensions W x H x D 425 5 x 144 3 x 508 0 mm 16 75 x 5 68 x 20 00 in Surrounding Envelope 628 7 x 152 5 x 762 0 mm 24 75 x 6 00 x 30 00 in Weight approx 15 Kg 33 lbs...

Page 5: ...arking Software is a Windows based operating software package that comes standard with the laser marking system It is a graphical user interface that makes marking pattern design quick and easy The WY...

Page 6: ...be taken into account when installing the auxiliary controller concerning contaminants and EMI susceptibility For details refer to the Installation Maintenance Manual supplied with the controller Com...

Page 7: ...ype V can provide data to a variable text string in the pattern or poll the pattern for data P Message Type P can load a pattern or poll the system for the current pattern name O Message Type O places...