1.    STANDARDS 

 
All Telenetics dial-up modems are designed to meet the following Standards: 
 
USA:   

FCC Part 15, Class A and Part 68 

 
Canada:  

DOC Standards CS-01, CS-02 and CS-03 

 

CANADIAN DEPARTMENT OF COMMUNICATION NOTICE 

 
NOTICE:  The Canadian Department of Communications (DOC) label identifies certified 
equipment.  This certification means that the equipment meets certain telecommunications network 
protective, operational and safety requirements.  The department does not guarantee the equipment 
will operate to the user’s satisfaction. 
 
Before installing this equipment, make sure you are permitted to connect it to the facilities of the 
local telecommunications company.  You must install the equipment using an acceptable method of 
connection.  In some cases you may also extend the company’s inside wiring for single line 
individual service by means of certified connector assembly (telephone extension cord).  You should 
be aware, however, that compliance with the above conditions may not prevent degradation of 
service in some situations. 
 
Repairs to certified equipment should be made by an authorized Canadian maintenance facility 
designed by the supplier.  Any repairs or alterations made by a user to this equipment, or equipment 
malfunctions, may give the telephone communications company cause to request the user to 
disconnect the equipment. 
 
For your own protection, make sure that the electrical ground connections of the power utility, 
telephone lines and internal metallic water pipe system, if present, are connected together.  This 
precaution may be particularly important in rural areas. 
 
Caution:  Do not attempt to make electrical ground connections yourself, contact the appropriate 
electric inspection authority or an electrician. 
 
NOTICE:  The load number (LN) assigned to each terminal device denotes the percentage of the 
total load to the telephone loop used by the device, to prevent overloading.  The termination on a 
loop may consist of any combination of devices, subject to the requirement that the total of the load 
numbers of all the devices does not exceed 100. 

Summary of Contents for MIU14.4

Page 1: ...Document No 49 0002 001 Rev A Installation Operation Diagnostics for the MIU2 4 MIU9 6 MIU14 4 MIU28 8 Industrial Grade Dial Modems Book 1 of 2 See Book 2 for AT Commands...

Page 2: ...Document No 49 0002 001 Rev A Telenetics Corporation 26772 Vista Terrace Drive Lake Forest California 92630 949 455 4000 Fax 949 455 4010...

Page 3: ...IONS Page 5 4 POWER MODES Page 6 5 MODEM SPECIFICATIONS Page 7 6 POWER CONNECTIONS Page 8 7 SERIAL DATA PORT PIN OUTS Page 9 8 DIP SWITCHES Page 10 9 LED INDICATOR Page 11 10 AUTO RESET FEATURE Page 1...

Page 4: ...d You should be aware however that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadia...

Page 5: ...found in utility substations and industrial facilities Though functionally similar to commercial modems the MIU includes special features that make it particularly well suited for utility and industr...

Page 6: ...enclosure Designed for unmanned locations the MIUs do not include the array of pushbuttons and LEDs normally associated with consumer type modems Configuration is by dip switches and or software AT co...

Page 7: ...des MIU2 4 12VDC 24VDC 125VDC 120VAC 220VAC 65mA 27mA 7 5mA 6 5mA 5 5mA MIU9 6 12VDC 24VDC 125VDC 120VAC 220VAC 115mA 57mA 11mA 10mA 9mA MIU14 4 12VDC 24VDC 125VDC 120VAC 220VAC 160mA 69mA 14mA 12mA 9...

Page 8: ...modem will instantly wake up to full power by either an incoming ring signal or any transmit data TxD signal Approx 6mA Power Down If the modem is on hook for 30 seconds it will automatically turn of...

Page 9: ...32 V 22bis V 22 Bell212A Bell 103 Modem Line Speed Asynch 2400bps 1200bps 300bps 2400bps 1200bps 300bps 14400bps 9600bps 4800bps 2400bps 1200bps 300bps 28800bps 19200bps 14400bps 9600bps 4800bps 2400b...

Page 10: ...MIU Installation Operation Diagnostics Edition March 30 1998 Page 8 6 POWER CONNECTIONS...

Page 11: ...MIU Installation Operation Diagnostics Edition March 30 1998 Page 9 7 SERIAL DATA PORT PIN OUTS...

Page 12: ...MIU Installation Operation Diagnostics Edition March 30 1998 Page 10 8 DIP SWITCH SETTINGS Not Applicable...

Page 13: ...o 6 times The Auto Reset feature is enabled and disabled by a dip switch on the modem module Your MIU will have been shipped with the Auto Reset mode active unless otherwise specified at the time of o...

Page 14: ...MIU Installation Operation Diagnostics Edition March 30 1998 Page 12 12 OUTLINE DRAWING MOUNTING...

Page 15: ...modem will have left the Telenetics factory in the configuration detailed on the following pages The Telenetics factory configuration differs from the Rockwell default configuration as follows C0 Roc...

Page 16: ...002 S09 006 S10 014 S12 050 S14 AAH S16 00H S S18 000 S21 00H S22 76H S23 15H S25 005 S26 001 S27 40H S28 00H STORED PROFILE 0 B1 E1 L2 M1 Q0 V1 X4 Y0 C1 D0 G0 J0 L0 P0 Q0 R0 S0 X0 S00 001 S14 AAH S18...

Page 17: ...26 001 S36 007 S37 000 S38 020 S44 020 S46 138 S48 007 S95 000 STORED PROFILE 0 B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 C1 D2 G0 J0 K3 Q5 R1 S0 T5 X0 S00 001 S02 043 S06 002 S07 050 S08 002 S09 006 S10 014 S1...

Page 18: ...26 001 S36 007 S37 000 S38 020 S44 020 S46 138 S48 007 S95 000 STORED PROFILE 0 B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 C1 D2 G0 J0 K3 Q5 R1 S0 T5 X0 S00 001 S02 043 S06 002 S07 050 S08 002 S09 006 S10 014 S1...

Page 19: ...05 S26 001 S36 007 S37 000 S38 020 S46 138 S48 007 S95 000 STORED PROFILE 0 B0 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 C1 D0 G2 J0 K3 Q5 R1 S0 T4 X0 S00 001 S02 043 S06 002 S07 030 S08 002 S09 006 S10 014 S11 09...

Page 20: ...agnosing communication problems and thereby isolating the problem at either the local modem the remote modem or the interconnecting line The following AT Tn commands form part of the CCITT V 54 protoc...

Page 21: ...is in effect the analog loopback state is entered and the test timer is set to the value in S18 A connect result code is sent to the DTE and the test timer then begins its count down The test terminat...

Page 22: ...the test must be terminated by a T0 H0 or Z command The latter two result in the modem going on hook If S18 does not contain 0 the test is terminated after the number of seconds stored in S18 RESULT C...

Page 23: ...he remote modem DSR is turned off if S1 is in effect the on line state is entered a CONNECT result code is sent to the DTE and the test timer is set to the value in S18 If the local modem does not rec...

Page 24: ...lt code is sent to the DTE and the test timer is set to the value in S18 While the test is active the local modem sends a test message to the remote modem and counts the errors in the received looped...

Page 25: ...t condition is entered and an OK result code is sent to the DTE During the test the modem sends a test message and counts errors in the looped back signal The test is terminated when the timer times o...

Page 26: ...MIU Installation Operation Diagnostics Edition March 30 1998 Page 24...

Page 27: ...MIU Installation Operation Diagnostics Edition March 30 1998 Page 25...

Page 28: ...MIU Installation Operation Diagnostics Edition March 30 1998 Page 26...

Page 29: ...the modem DATA PUMP interface This signal is also dependent on the DAA circuit Telco Interface Returns the higher order byte of the EQM Eye Quality Monitor is the filter squared magnitude of the erro...

Page 30: ...modem is asynchronous only 8 Modems could not find a common framing technique 9 Modems could not find a protocol in common 10 Feature negotiation message sent by other modem incorrect 11 Synchronous i...

Page 31: ...MIU Installation Operation Diagnostics Edition March 30 1998 Page 29 NOTES...

Reviews: