MIU Installation, Operation & Diagnostics Edition: March 30, 1998 Page 13
13. MODEM CONFIGURATION
Telenetics dial and leased line modems are based upon Rockwell
chipsets. These chipsets contain Rockwell’s “AT” command set.
A summary of the Rockwell command set for your MIU modem is
provided in
Book 2.
Unless otherwise specified at the time of order, your modem will have
left the Telenetics factory in the configuration detailed on the following
pages.
The Telenetics factory configuration differs from the Rockwell default
configuration as follows...
&C0
Rockwell Default
Carrier Detect (CD) always ON.
&C1
Telenetics Factory
Carrier Detect (CD) only ON
when
modem
connected (on hook)
S0=0 Rockwell
Default
Auto-Answer
OFF
S0=1 Telenetics
Factory Auto-Answer on first ring
You can review the configuration of your modem by entering AT&V
<CR>.
You can restore the Rockwell factory configuration by entering
AT&F&W