1  DESCRIPTION 

The  portable 

datalogger

  model  PFC-12  is  designed  to  read  the  data from  a 

Telemac’s 

dual coil vibrating wire sensor. Readings can be taken in sustained mode or dampened. 
The temperature reading is also possible by measuring the resistance of the output coil 
of the sensor.

 

1.1  GENERAL DESCRIPTION 

The PFC-12 datalogger is integrated in an impact resistant casing made of ABS plastic. 

Once the lid is closed, the unit is completely waterproof. Opened, the reading station is 
splash proof.

   

Included with the PFC-12 are a battery charger, a USB cable and 

two sets of cables in 

order  to  allow  connection  to  various  sensors.    The  unit  is  powered  by  a  rechargeable 
battery.  When the battery is fully charged, the unit can be used over 8 hours.  

 

An interactive menu interface facilitates the use of the unit. A graphic backlit LCD 64 x 
128 pixels displays the frequency and temperature readings simultaneously. 

1.2  FRONT PANEL 

Located  on  the  front  panel  of  the  PFC-12  are  a  switch,  connectors, 

and  a  removable 

module integrating a monitor and a keyboard.

 

 

Figure 1: Front panel of the PFC-12 

 

Summary of Contents for PFC-12

Page 1: ...Its misuse is potentially dangerous The Company makes no warranty as to the information furnished in this manual and assumes no liability for damages resulting from the installation or use of this pro...

Page 2: ...OF CONTENTS 1 DESCRIPTION 1 1 1 GENERAL DESCRIPTION 1 1 2 FRONT PANEL 1 1 2 1 CONNECTORS 2 1 2 2 KEYBOARD 2 2 HOW TO USE THE UNIT 2 3 MAINTENANCE 4 4 TROUBLESHOOTING 5 4 1 UNSTABLE READING 5 4 2 NO RE...

Page 3: ...is completely waterproof Opened the reading station is splash proof Included with the PFC 12 are a battery charger a USB cable and two sets of cables in order to allow connection to various sensors T...

Page 4: ...Jaegger connector 1 2 2 KEYBOARD The keyboard includes 4 white arrows used to move the cursor Enter used to select or enter information Esc used to navigate the menu Shift Press 1 2 or even 3 times o...

Page 5: ...ery voltage drop below 11 3 V If necessary select Display settings to activate the backlight and self closing and to adjust the contrast required to use the item at low temperature Select Configuratio...

Page 6: ...ect Recording and activate the recording function by selecting YES Then leave the power switch enabled to allow continuous acquisition The screen will turn off after a while Simply press a key on the...

Page 7: ...sensor and cable Check the connection between the cable and the unit Check to see if the same problem occurs with other sensors using the same reading mode Is the environment quiet Are there other ac...