User Guide
PAGE 82
Example of Entry/Exit Zone
WITH
Security Switch Usage
For Entry Zone:
The entry delay is the period of time between entering the surveillance zone and reaching
the digital video recorder. In order to disarm the system for maintenance or repair, user /
installer needs to turn off the security switch and enter the surveillance zone. The delay
timer starts from the 1st trigger by the 1st alarm sensor (i.e. Alarm 4). Note that if user
enables recording action, recording action is automatically activated during entry delay.
The detail description is shown as follows:
1. User turns off security switch
2. The alarm is set at entry delay
3. The 1st trigger is made by Alarm 4 (i.e. user enters the surveillance zone and the entry
delay time begins)
4. 2nd, 3rd and 4th trigger are made and each entry delay starts respectively
5. User disarms the system for maintenance
For example: If the time for going from security switch to digital video recorder is about 8
minutes, Delay 4 should be around 8 minutes, while Delay 3 should be longer than the
time for going from security switch to Alarm 3, and so on.