SAFETY INSTRUCTION 

Power cord for the United Kingdom 

When using T3PS36006 in the United Kingdom, make sure the 
power cord meets the following safety instructions. 

 

NOTE: This lead/appliance must only be wired by competent persons  

WARNING: THIS APPLIANCE MUST BE EARTHED 

IMPORTANT: The wires in this lead are coloured in accordance with 
the following code: 
Green/ Yellow: 

Earth 

 

Blue: 

Neutral 

Brown: 

Live (Phase) 

As the colours of the wires in main leads may not correspond with the 
colours marking identified in your plug/appliance, proceed as follows: 
The wire which is coloured Green & Yellow must be connected to the 
Earth terminal marked with the letter E or by the earth symbol  or 
coloured Green or Green & Yellow. 
The wire which is coloured Blue must be connected to the terminal 
which is marked with the letter N or coloured Blue or Black. 
The wire which is coloured Brown must be connected to the terminal 
marked with the letter L or P or coloured Brown or Red. 
If in doubt, consult the instructions provided with the equipment or 
contact the supplier. 
This cable/appliance should be protected by a suitably rated and 
approved HBC mains fuse: refer to the rating information on the 
equipment and/or user instructions for details. As a guide, cable of 
0.75mm

2

 should be protected by a 3A or 5A fuse. Larger conductors 

would normally require 13A types, depending on the connection 
method used. 
Any moulded mains connector that requires removal /replacement 
must be destroyed by removal of any fuse & fuse carrier and disposed 
of immediately, as a plug with bared wires is hazardous if a engaged in 
live socket. Any re-wiring must be carried out in accordance with the 
information detailed on this label.

Summary of Contents for T3PS36006

Page 1: ... ...

Page 2: ...opied reproduced or translated to another language without prior written consent of Teledyne LeCroy company The information in this manual was correct at the time of printing However Teledyne LeCroy continues to improve products and reserves the rights to change specification equipment and maintenance procedures at any time without notice ...

Page 3: ...INSTRUCTION 4 OVERVIEW 8 T3PS36006 Main Features 9 Front Panel Overview 10 Rear Panel Overview 13 SETUP 14 Installation Location 15 Power Up 16 Over Voltage Protection Setup 17 Load Cable Connection 19 Output On Off 20 APPENDIX 22 Specification 22 ...

Page 4: ...ety and to keep the best condition for T3PS36006 Safety Symbols These safety symbols may appear in this manual or on T3PS36006 WARNING Warning Identifies conditions or practices that could result in injury or loss of life CAUTION Caution Identifies conditions or practices that could result in damage to T3PS36006 or to other properties DANGER High Voltage Attention Refer to the Manual Protective Co...

Page 5: ...easurement categories EN 61010 1 2010 specifies the measurement categories and their requirements as follows T3PS36006 falls under category I Measurement category IV is for measurement performed at the source of low voltage installation Measurement category III is for measurement performed in the building installation Measurement category II is for measurement performed on the circuits directly co...

Page 6: ...ollution degrees and their requirements as follows T3PS36006 falls under degree 2 Pollution refers to addition of foreign matter solid liquid or gaseous ionized gases that may produce a reduction of dielectric strength or surface resistivity Pollution degree 1 No pollution or only dry non conductive pollution occurs The pollution has no influence Pollution degree 2 Normally only non conductive pol...

Page 7: ...t be connected to the terminal which is marked with the letter N or coloured Blue or Black The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red If in doubt consult the instructions provided with the equipment or contact the supplier This cable appliance should be protected by a suitably rated and approved HBC mains fuse refer to ...

Page 8: ...006 in a nutshell including its main features and front rear panel introduction After going through the overview follow the Setup chapter page 14 to properly power up and set operation environment T3PS36006 Main Features 9 Front Panel Overview 10 Rear Panel Overview 13 ...

Page 9: ...00ppm C 3mV 150ppm C 3mA Compact size light weight 6kg Operation Constant voltage operation Constant current operation Tracking Series operation Tracking Parallel operation Output On Off control 3 outputs with full Voltage control Output range selection for CH1 and CH2 60V 3A or 30V 6A LED display Protection Over voltage protection OVP Overload protection Reverse polarity protection Interface Remo...

Page 10: ...t Key Power Switch OVP Indicator CH2 Output Knob CH2 Indicator CH2 Output Terminal Ground Terminal Tracking Mode Switches CH3 Overload Indicator CH3 Voltage Knob CH3 Output Terminal CH1 Output Knob CH1 Indicator CH1 Output Terminal Power switch POWER Turns On or Off the main power OVP indicator O V P SET TRIP Turns green during the OVP setup Turns red tripped when the output Voltage exceeds the se...

Page 11: ...Displays Channel 1 or Channel 3 current A and voltage V The switch on the right selects the channel 1 up or 3 down C 1 C 3 CH1 CH3 Channel 3 overload indicator OVER LOAD Turns red when Channel 3 output exceeds the current rating 3A Channel 3 switches from Constant Voltage CV mode to Constant Current CC mode Channel 1 2 3 output terminal CH3 0 1 5V 3A Accepts the load cables ...

Page 12: ...tage CV mode red in Constant Current CC mode Channel 2 CV CC PAR indicator C V C C PAR Independent mode Turns green in Constant Voltage CV mode red in Constant Current CC mode When operating in the Tracking Parallel mode the Channel 2 indicator always stays red PAR Channel 1 indicator shows the CV CC status ...

Page 13: ...ting Point Remote Control Terminal Power Cord Fuse Socket Cooling Fan WARNING Remote control terminal Accepts remote output On Off control connection OVP setting point C 3 C C 1 NOR AL O V P Set Activates Over Voltage Protection OVP and sets the protection threshold for channel 1 2 3 Power cord fuse socket The power cord socket accepts the AC mains 115V 230V 50 60Hz The fuse holder contains the AC...

Page 14: ...t Guide 14 SETUP This chapter describes how to properly power up and configure T3PS36006 before the operation Installation Location 15 Power Up 16 Over Voltage Protection Setup 17 Load Cable Connection 19 Output On Off 20 ...

Page 15: ...ce Leave at least 3cm around T3PS36006 to the left and right 3cm 3cm Cooling fan opening The cooling fan is located on the rear panel Allocate extra space on the back of T3PS36006 so that the cooling fan opening would not become blocked Cooling Fan ...

Page 16: ...dicators and meters turn On VOLTAGE VOLTAGE CURRENT CURRENT CH2 CH1 SLAVE MASTER C V C V C C C C PAR VOLTAGE VOLTAGE CURRENT CURRENT CH2 CH1 SLAVE MASTER C V C V C C C C PAR CH1 CH3 CH CH1 CH3 CH Power Off Press the Power switch again to turn Off the power After two seconds the meters and indicators turn Off ...

Page 17: ...iately OVP setup 1 Slide the rear panel switch to the O V P SET position C 3 C C 1 NOR AL O V P Set 2 The OVP indicator on the front panel turns green indicating OVP setup O V P SET TRIP 3 The Voltage meters show the OVP setting level instead of the output level The Current meters show zero 0 00 CH1 CH3 CH1 CH3 4 Adjust the OVP level using the rear panel terminal The setting on the front panel met...

Page 18: ...tch to the Normal position The OVP indicator on the front panel turns Off C 3 C C 1 NOR AL O V P Set O V P SET TRIP O V P SET TRIP When OVP is activated The OVP activates when one of channel 1 2 3 output voltage exceeds the OVP setting The indicator turns red tripped and the output is shut Off immediately O V P SET TRIP O V P SET TRIP ON OFF OUTPUT OUTPUT ON OFF ...

Page 19: ...en the screw 0 60V 3A 0 30V 6A 3 Banana plug Insert the plug into the socket 0 60V 3A Wire type When using load cables other than the attached make sure they have enough current capacity for minimizing cable loss and load line impedance Voltage drop across a wire should not excess 0 5V The following list is the wire current rating at 450A cm2 Wire size AWG Maximum current A 20 2 5 18 4 16 6 14 10 ...

Page 20: ...tic Output Off Any of the following actions during output On automatically turns it Off They might involve sudden and harmful change in the output level Change the range 60V 3A 30V 6A Change the tracking SW between independent series parallel TRACKING INDEP SERIES PARALLEL OVP tripped O V P SET TRIP O V P SET TRIP OVP SET mode C 3 C C 1 NOR AL O V P Set Remote control When in remote control mode f...

Page 21: ...SETUP 21 CV CC red without output Red CV CC indicator when output Off indicates internal error Contact the service center C V C C OUTPUT ON OFF ...

Page 22: ...0 1 5V 3A Voltage Regulation Line 0 01 3mV Load 0 01 5mV rating current 6A 0 01 8mV rating current 12A Ripple Noise 5mVrms 5Hz 1MHz 50mVP P 20Hz 20MHz Recovery Time 100µs 50 load change minimum load 0 5A Current Regulation Line 0 2 3mA Load 0 2 3mA Ripple Noise 3mArms Tracking Operation Tracking Error 0 5 10mV of Master Series Regulation 300mV Ripple Noise 10mVrms 5Hz 1MHz 100mVpp 20Hz 20MHz ...

Page 23: ... above DC 1000V Chassis and AC cord 100MΩ or above DC 1000V Temperature Coefficient Voltage 100ppm C 3mV Current 150ppm C 3mA Remote Control Output On Off Fan Noise 50dB Operation Environment Ambient temperature 0 40 C Relative humidity 80 Storage Environment Ambient temperature 10 70 C Relative humidity 70 Power Source AC 115V 230V 15 50 60Hz Accessories Quick Start Guide x 1 Power cord x 3 Test ...

Page 24: ... 0 0 0 1 2 3 4 5 6 7 8 8 9 3 3 3 45 6 990 0 0 9 0 0 0 9 0 0 0 0 9 7 7 88 8 1 931346 00 RevA ...

Reviews: