40
Operation
SeaBat UI - User Manual
4.8.2 Status
Figure 4-48
Status raw data recording
The Status displayed the status of the Raw Data Recording with the
current file size of the recording file and the number of records that are
added to the recording file.
Hover the pointer over the selected records field will display all the logged
records, as selected in the record selection.
With increased range and/or ping rates, the recording files will become
quickly very large. It is best to monitor the file sizes and ensure that 10%
of the disk space is always left available for system operation. Therefore it
is advisable to record the data on a separate hard disk and not on C:\.
4.9 Hardware
In the Hardware the operator can setup the following:
Motion Stabilization (see below)
PPS Configuration (see page 42)
Trigger Configuration (see page 43)
Ping Settings (see page 43)
Bracket (see page 45)
Normalization details (see page 46)
Dual Head (see page 44)
On top of the Hardware pane the sonar IP Address has to be set. Select
from the available IP Addresses on the local network the one that is valid
for the sonar. In the selection the IP Address of the local system gets the
text ‘(local)’ behind the IP Address.
Figure 4-49
Hardware part where the sonar IP Address can be selected