Q-Lite Satellite Modem Installation and Operating Handbook
6-84
the front panel these go back to their factory defaults. This is done in order not to lose
remote control of the modem from the web user interface when using it.
LOAD_DEFAULTS
cannot be erased or overwritten.
Configuration memory names are restricted to alphanumeric characters.
Figure 6-32 Edit->Memories Screen
6.2.9.1 Edit->Memories->Recall Screen
The
Edit->Memories->Recall
screen (shown in
Figure 6-33
) displays all of the
configuration memories that are stored on the modem. A specific configuration memory
can be made active by selecting the associated
Recall
button. The
Delete
button can be
used to delete a configuration memory.
Figure 6-33 Edit->Memories->Recall Screen
6.2.9.2 Edit->Memories->Recall->Advanced Reversionary Control Screen
The
Edit->Memories->Recall->Advanced
screen (shown in
Figure 6-34
) supports a
method for recovering a remote modem from a failure during a change to the modem’s
configuration. In essence, this works in a similar way to the Cisco Reload command,
where a known trusted configuration is loaded after a defined timeout period in the event
that the reload operation is not cancelled by the operator in a timely manner after
completing the necessary configuration changes.