Measuring sensors
Gas
Measuring
range
(ppm)
ADF
sensor
IS
sensor
Temperature
range
(°C)
% HR
Accuracy (ppm)
@20°C
Average
LifeExpe
ctancy
(months)
Resp. Time
T50/T90
(s)
Storage
time and
conditions
Combustible gas
Infrared
GD10P
0-100%
LEL
-20 to +60 0 – 99
+/- 3% (from 0 to 50%
LEL)
+/- 5% (from 50 to 100%
LEL)
>60
1/2
(CH4)
3/6
(CH4)
(a)
Catalytic
0-100%
LEL
-20 to +60 0 - 95
+/-1 % LEL(from 0 to 70%
LEL)
40
6/15
(CH4)
(b)
AsH3
Arsine
1.00
-20 to +40 20 – 90
+/- 0,05
18
30/120
(a)
Cl2
Chlorine
10.0
-20 to +40 10 – 90
+/- 0,4
24
10/60
(a)
ClO2
Chlorine
Dioxide
3.00
-20 to +40 10 – 90
+/- 0,3
24
20/120
(a)
CO
Carbon
Monoxide
100
300
1000
-20 to +50 15 – 90
+/- 3 (range 0-100)
40
15/40
(a)
CO2
Carbon
Dioxide
0-5% vol.
-20 to +55 0 – 95
+/- 3%
48
11/30
(a)
COCl2
Phosgene
1.00
-20 to +40 15 – 90
+/- 0,05
12
60/180
(c)
ETO
Ethylene Oxide 30.0
-20 to +50 15 – 90
+/- 1,0
36
50/240
(a)
H2
Hydrogen
2000
-20 to +50 15 – 90
+/- 5%
24
30/50
(a)
H2S
Hydrogen
Sulphide
30.0
100
1000
-20 to +50 15 – 90
+/- 1.5 (range 0-30)
36
15/30
(a)
HCl
Hydrogen
Chloride
30.0
100
-20 to +40 15 - 95
+/- 0.4 (range 0-30)
24
30/150
(a)
HCN
Hydrogen
Cyanide
10.0
30.0
-25 to +40 15 - 95
+/- 0.3 (range 0-10)
18
30/120
(c)
HF
Hydrogen
Fluoride
10.0
-10 to +30 20 – 80
+/- 5%
12
40/90
(c)
NH3
Ammonia
100
1000
5000
-20 to +40 15 – 90
+/- 5
+/- 20
+/- 150 or 10%
24
50/90
50/90
50/120
(a)
NO
Nitrogen
Monoxide
100
300
1000
-20 to +50 15 – 90
+/- 2 (range 0-100)
36
10/30
(a)
NO2
Nitrogen
Dioxide
30.0
-20 to +50 15-90
+/-0,8
24
30/60
(a)
O2
Oxygen
(>2years)
0-30%
vol.
-20 to +50 15 – 90
0.4% Vol. (from 15 to 22%
O2)
28
6/15
(a)
O2
Oxygen
(>5years)
0-30%
vol.
-40 to +50 15 – 90
+/-1.5%
60
15/25
(a)
Summary of Contents for OLCT 60
Page 1: ...NPO60GB Revision F 2 OLCT 60 FIXED POINTGAS MONITOR USER MANUAL ...
Page 44: ...OLCT 60 FIXED POINTGAS MONITOR USER MANUAL 38 NPO60GB Revision F 2 ...
Page 50: ...OLCT 60 FIXED POINTGAS MONITOR USER MANUAL 44 NPO60GB Revision F 2 ...
Page 52: ...OLCT 60 FIXED POINTGAS MONITOR USER MANUAL 46 NPO60GB Revision F 2 ...
Page 66: ...OLCT 60 FIXED POINTGAS MONITOR USER MANUAL 60 NPO60GB Revision F 2 ...
Page 67: ...OLCT 60 FIXED POINTGAS MONITOR USER MANUAL NPO60GB Revision F 2 61 ...