![Teledyne Mini Compact Outdoor Operation Manual Download Page 18](http://html.mh-extra.com/html/teledyne/mini-compact-outdoor/mini-compact-outdoor_operation-manual_1080382018.webp)
18
208143 REV C
Operations Manual, HPA3, Mini Compact Outdoor SSPA
2.2.8 Auxiliary Power Port (J8) [MS3112E10-6S]
The +15 VDC Output, J8, is located on the bottom side of the amplifier as shown in Figure
2-1. This pr15 VDC and up to 1 Amp current to any external equipment. It is a 6-pin
MS-type connector. See
Table 2-6
.
2.2.9 Chassis Ground Pin
A Chassis ground terminal is provided on the bottom side of the amplifier. A ¼ - 20 threaded
terminal is provided for equipment grounding.
2.3 Physical Features
In addition to the I/O connectors, the Mini Compact Outdoor user-friendly features include a
summary alarm indicator and a removable fan tray.
2.3.1 Summary Alarm Indicator
A summary alarm indicator LED is located on the input side of the amplifier. When the SSPA
is online, this indicator illuminates GREEN. When in a fault condition, it illuminates RED.
Table 2-5: Power Requirements
Model Number
RF Output (P
sat
)
RF Output (P
1dB
)
AC Input w/ RF
HPACC3075AC_XXXX
48.8 dBm (76W)
48.5 dBm (70W)
550 W
HPACC3100AC_XXXX
50.0 dBm (100W)
49.5 dBm (89W)
660 W
HPACC3175AC_XXXX
52.5 dBm (175W)
48.5 dBm (70W)
◊
1100
W
HPAXX3050AC_XXXX
47.0 dBm (50W)
46.5 dBm (45W)
465 W
HPAXX3075AC_XXXX
48.8 dBm (76W)
48.3 dBm (68W)
600 W
HPAXX3100AC_XXXX
50.0 dBm (100W)
49.5 dBm (89W)
710 W
HPAXX3175AC_XXXX
52.5 dBm (175W)
48.5 dBm (70W)
◊
1120
W
HPAKU3050AC_XXXX
47.0 dBm (50W)
46.0 dBm (40W)
665 W
HPAKU3080AC_XXXX
49.0 dBm (80W)
45.0 dBm (32W)
◊
820
W
◊
at P
LINEAR
rather than P
1dB
Table 2-6: J8 Auxiliary Power Port Pin-Outs
Pin #
Connection
Pin #
Connection
A
External Fault IN
D
Ground
B
Fault Pullup
E
+15V External
C +15V
LNA F Ground