76
•
Appendix B: ASCII Commands
Linea CL Series Camera
RPC: Reset Flatfield Coefficients
Display
Name
Reset Flatfield Coefficients
Mnemonic
RPC
Argument(s)
Description
Reset all user FPN values to zero and all user PRNU coefficients to one
Notes
SAC: Set AOI Count
Display
Name
Set AOI Count
Mnemonic
SAC
Argument(s) Number of AOI’s
1 to 4
Description
Set AOI Counter
SAD: Set AOI Selector
Display
Name
Set AOI Selector
Mnemonic
SAD
Argument(s) Selector
1 to 4
Offset
1 to AOI Count – any pixel can be starting pixel
Width
No less than 40 pixels
Description
Define an AOI
Notes
•
Must not overlap with an already existing AOI
SAM: Set AOI Mode
Display
Name
Set AOI Mode
Mnemonic
SAM
Argument(s) Mode
0.
Off / Disable
1.
Active / Enable
Description
Set AOI mode
Notes
SBH: Set Binning Horizontal
Display
Name
Set Binning Horizontal
Mnemonic
SBH
Argument(s) Binning
1.
Single pixel
2.
Binning of 2 pixels
Description