3 RU SSPA Chassis Operations Manual
2.2.6.5 Priority
For use in 1:2 redundant systems. Allows the user to select Polarity 1 or Polarity 2. If
the online amplifiers for Polarity 1 and Polarity 2 simultaneously enter a faulted state,
the standby amplifier will switch to the selected polarity.
2.2.6.6 N+1 System Operation Parameters
Under this set of menus, the user may select or adjust important N+1 options.
2.2.6.6.1 N+1 Array Size
This menu sets the type of N+1 system or disables N+1 operation for this unit. Choices
include the following: Disable N+1; System of 2 units; System of 4 units; System of 8
units; or System of 16 units. A single 5RU chassis in N+1 operation utilizes a system of
2 units.
Units connected to a N+1 system must have an identical N+1 array selection or have
N+1 operation disabled. A unit connected to a N+1 link cable with the N+1 option disa-
bled will not be controlled by a N+1 Master. To the Master unit, it will appear as a fault-
ed chassis.
2.2.6.6.2 N+1 Address
This option allows the selection of the unit’s N+1 priority address. All units in a N+1
array must be unique and with a contiguous N+1 address.
The unit with the lowest N+1 address has the highest priority when the system selects
a new Master unit in the event of the failure of the assigned Master unit. A unit with Ad-
dress 1 will be the default Master unit. If Unit 1 fails, Unit 2 will take its place as the
Master unit.
2.2.6.6.3 Auto Gain Control
This option allows the user to enable or disable the N+1 Automatic Gain options.
•
1.AutoGain 5dB
— When Auto Gain is enabled, the system will automat-
ically back off from maximum linear gain and reserve 5 dB of attenuator
range for gain compensation. When this option is enabled, the N+1 Mas-
ter unit default System Information page will display: AutoGain(dB):XX.X
•
2.AutoGain Off
— When Auto Gain is disabled, the system can be ad-
justed as if it was a single SSPA unit, attenuating system gain between 0
and 20 dBm. System gain will not apply automatic gain compensation if
any of the units in the N+1 redundancy array fails. When this option is
disabled, the Master unit default System Information page will display:
SSPAGain(dB):XX.X.
Summary of Contents for HPAC-2005
Page 18: ...18 205356 REV T 3 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 64: ...64 205356 REV T 3 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 100: ...100 205356 REV T 3 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 144: ...144 205356 REV T 3 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 156: ...156 205356 REV T 3 RU SSPA Chassis Operations Manual THIS PAGE LEFT INTENTIONALLY BLANK ...