Teledyne HASTINGS 200 Series Instruction Manual Download Page 17

126B - PAGE 17

5.0  REPLACEMENT PARTS

The following is a list of the available replacement parts and their factory stock numbers. The HFM-
229, HFM-229B, HFM-200, HFM-200B, and the HFC-202 shunts and filter discs are interchange-
able. The HFM-230, HFM-201, and the HFC-203 shunts and filter discs are also interchangeable. The
same sensor module is used on all of the above models.

ST

ST

ST

ST

STOCK NO

OCK NO

OCK NO

OCK NO

OCK NO..... DESCRIPTION

DESCRIPTION

DESCRIPTION

DESCRIPTION

DESCRIPTION

AIR RANGE

AIR RANGE

AIR RANGE

AIR RANGE

AIR RANGE

81-102L......... LOW RANGE SHUNT ..................................................... 10, 30, 50, 100, 250 SCCM

81-102H ........ MED RANGE SHUNT ....................................................... 0.3, 1, 3, 5, 10, 30 SLPM

81-102B......... HIGH RANGE SHUNT ............................................... 50, 100, 150, 300, 500 SLPM

65-140E......... LFE Model LS-2, 2.0" NPTM ................................................................. 0-750 SLPM

65-140G ........ LFE Model LS-3, 3.0" NPTM ............................................................... 0-1500 SLPM

65-140J .......... LFE Model LS-4F, 4.0" Flange ............................................................... 0-3000 SLPM

65-140K ........ LFE Model LS-6F, 6.0" Flange ............................................................... 0-6000 SLPM

65-140L......... LFE Model LS-8F, 8.0" Flange ............................................................ 0-15,000 SLPM

39-02-003 ...... SMALL FILTER DISC ................................................. HFM-229, HFM-229B, AND

HFC-202

39-02-002 ...... LARGE FILTER DISC ...................................................... HFM-230 AND HFC-203

81-105 ........... SENSOR MODULE ........................................................................... ALL MODELS

65-595 ........... FAST RESPONSE HFM ELECTRONICS CARD ...................... D CONNECTOR

81-115 .....................................................................VITON O-RING KIT FOR HFM-200 and 200B

81-116 ..................................................................................... VITON O-RING KIT FOR HFM-201

81-146 .............................................................. KALREZ

TM

 O-RING KIT FOR HFM-200 and 200B

81-147 .............................................................................. KALREZ

TM

 O-RING KIT FOR HFM-201

81-150 ............................................................ NEOPRENE O-RING KIT FOR HFM-200 and 200B

81-151 ............................................................................ NEOPRENE O-RING KIT FOR HFM-201

NO

NO

NO

NO

NOTE

TE

TE

TE

TE:  Ranges listed are for same standard temperature and pressure.

To place an order or to obtain information concerning replacement parts, contact the factory or our
local manufacturer’s representative in your area. See below, or this manual’s last page for the address or
phone number. When ordering, include the following information:

• Instrument model number

• Part description

• Hastings part number

Summary of Contents for HASTINGS 200 Series

Page 1: ...00 SERIES HASTINGS 200 SERIES HASTINGS 200 SERIES F F F F FAST RESPONSE AST RESPONSE AST RESPONSE AST RESPONSE AST RESPONSE MASS FLOWMETERS MASS FLOWMETERS MASS FLOWMETERS MASS FLOWMETERS MASS FLOWMETERS INSTRUCTION INSTRUMENTS TELEDYNE HASTINGS INSTRUCTION MANUAL ...

Page 2: ... should incorporate immediately into the manual Addenda are numbered sequentially When a new revision is created all addenda associated with the previous revision of the manual are incorporated into the new revision of the manual Each new revision includes a revised copy of this print history page Revision B Document Number 126 082000 August 2000 Revision C Document Number 126 082005 August 2005 H...

Page 3: ...4 Mechanical Connections 7 2 5 Electrical Connections 8 2 6 Operation 8 2 6 1 Power Supply Operation 8 2 6 2 AmbientTemperature 8 2 6 3 Zero Check 8 2 7 Range Changing 8 SECTION 3 0 THEORY OF OPERATION 9 3 1 Overall Functional Description 9 3 2 Sensor 9 3 3 Electronics 10 3 4 Shunt 10 SECTION 4 0 MAINTENANCE 13 4 1 Introduction 13 4 2 Authorized Maintenance 13 4 3 Adjustments 13 4 3 1 Calibration ...

Page 4: ... 15 SECTION 5 0 REPLACEMENT PARTS 17 SECTION 6 0 WARRANTY AND REPAIR 19 SECTION 7 0 DIAGRAMS AND DRAWINGS 21 AssemblyDiagram PC810FastReponse 22 Schematic PC 810 Fast Response 23 HFM 200 Outline Drawng 24 HFM 201 Outline Drawing 25 HFM 200B Outline Drawing 26 Laminar Flow Element Outline Drawing 27 ...

Page 5: ... a removable replaceable sensor which virtually eliminates long down time due to clogging the most common cause of failure in the industry Each flowmeter has a shunt which can be quickly and easily adjusted in the field to different ranges however recalibration is normally required A 100 micron filter is located upstream of the shunt and sensor to eliminate most of the larger impurities in the sys...

Page 6: ... 3 2 1 3 2 1 3 2 Alar Alar Alar Alar Alarms ms ms ms ms The Model AL 1 Flow Alarm is available as an attachment suitable for use with any 0 5 00VDC input signal Calibrated digital dial precision pots determine the low and high set points as a percent of full scale This permits use with any range flowmeter or other instrument having a 0 5 00VDC linear output signal Control action is within 0 2 of s...

Page 7: ...urge suppressers are recommended to prevent power line spikes from feeding through to the instruments These power requirements are satisfied by the Hastings Power Supply described in Section 1 4 Accessories 2 3 Output 2 3 Output 2 3 Output 2 3 Output 2 3 Output V V V V Voltage oltage oltage oltage oltage The output of the flowmeter is a 0 5 00VDC signal proportional to the flow rate The output is ...

Page 8: ...t transducers while the power supply is energized The display may read either percent of full scale or actual flow rate depending on the power supply purchased To read flow rate turn display switch to desired channel 2 6 2 2 6 2 2 6 2 2 6 2 2 6 2 Ambient Ambient Ambient Ambient Ambient T T T T Tempera empera empera empera emperature ture ture ture ture In order to maintain the accuracy of the flow...

Page 9: ... sensor and the shunt is always laminar The circuit board amplifies the sensor output to 5 00VDC and sends it to the power supply to display All of these components working together result in a fast stable flowmeter 3 2 Sensor 3 2 Sensor 3 2 Sensor 3 2 Sensor 3 2 Sensor The Hastings Model HFM Mass Flowmeter operates on a unique thermal electric principle whereby a metallic capillary tube is heated...

Page 10: ...rate ofchange of the input signal and adding it to the amplified input signal The elec tronics are adjusted to provide response times of less than two seconds to 98 of a 0 100 step change with less than 2 overshoot The electronics also maintain the ouput signal above 5 00VDC when the flowrate exceeds the full scale flow of the flowmeter NO NO NO NO NOTE TE TE TE TE The output signal will continue ...

Page 11: ...is adjustable from 0 50 slpm to 0 500 slpm The HFM 229B Series uses an external laminar flow element instead of an internal shunt because the necessary size for the element exceeds the body size of the flowmeter This laminar flow element is made of a corrugated and fused stainless steel ribbon similar to the one used in the Model HFM 230 Fig 3 7 Fig 3 7 Fig 3 7 Fig 3 7 Fig 3 7 ...

Page 12: ...126B PAGE 12 ...

Page 13: ... 4 4 4 4 4 Adjust SPAN pot until the flowmeter indicates full scale flow 5 000VDC NOTE Perform this step only if a calibrated reference flowmeter is avail able 5 5 5 5 5 Record flowmeter and flow reference outputs for flow rates of 20 40 60 80 and 100 4 3 2 Response 4 3 2 Response 4 3 2 Response 4 3 2 Response 4 3 2 Response Time Time Time Time Time Adjustments Adjustments Adjustments Adjustments ...

Page 14: ... 5 Range Changes 4 5 Range Changes Remove end cap and shunt assembly per Section 4 4 above The 0 10 sccm to 0 300 sccm range shunt has tubes while the medium range shunt is built from a coil of corrugated stainless steel foil The medium range shunt has a disk assembly with two large one medium and one small hole To change ranges the disc on the inlet of the shunt should be loosened turned and reti...

Page 15: ... and tighten down the three screws evenly Replacement of sensor will require recalibration per Section 4 3 1 4 8 4 8 4 8 4 8 4 8 T T T T Troubleshooting roubleshooting roubleshooting roubleshooting roubleshooting SYMPT SYMPT SYMPT SYMPT SYMPTOM OM OM OM OM Output reads 40 of flow with no flow Zero pot has no effect CA CA CA CA CAUSE USE USE USE USE Power supply locked up or shorted out A A A A ACT...

Page 16: ...an 0 00VDC with no flow or there is a small flow when flowmeter reads 0 00VDC CA CA CA CA CAUSE USE USE USE USE ZERO potentiometer is out of adjustment A A A A ACTION CTION CTION CTION CTION Shut off all flow Adjust ZERO potentiometer until output reads 0 00VDC SYMPTOM SYMPTOM SYMPTOM SYMPTOM SYMPTOM Flowmeter out of calibration and non linear CAUSE CAUSE CAUSE CAUSE CAUSE Leaks in gas inlet or ou...

Page 17: ...4 0 Flange 0 3000 SLPM 65 140K LFE Model LS 6F 6 0 Flange 0 6000 SLPM 65 140L LFE Model LS 8F 8 0 Flange 0 15 000 SLPM 39 02 003 SMALL FILTER DISC HFM 229 HFM 229B AND HFC 202 39 02 002 LARGE FILTER DISC HFM 230AND HFC 203 81 105 SENSOR MODULE ALL MODELS 65 595 FAST RESPONSE HFM ELECTRONICS CARD D CONNECTOR 81 115 VITON O RING KIT FOR HFM 200 and 200B 81 116 VITON O RING KIT FOR HFM 201 81 146 KAL...

Page 18: ...126B PAGE 18 ...

Page 19: ...nstruments determines in good faith that it is defective in materials or workmanship during the warranty period Defective instruments should be returned to Hastings Instruments together with a written statement of the problem and a Return MaterialAuthorization RMA number Please consult the factory for your RMA number before returning any product for repair Non W Non W Non W Non W Non War ar ar ar ...

Page 20: ...126B PAGE 20 ...

Page 21: ...126B PAGE 21 7 0 Diagrams and Drawings ...

Page 22: ...126B PAGE 22 PC 810Assembly InformationfromHastingsdrawing30837rev F ...

Page 23: ...126B PAGE 23 PC 810Schematic InformationfromHastingsdrawing30837rev F ...

Page 24: ...126B PAGE 24 ...

Page 25: ...126B PAGE 25 ...

Page 26: ...126B PAGE 26 ...

Page 27: ...126B PAGE 27 ...

Page 28: ...126B PAGE 28 ...

Reviews: