GT-FIRE
PORTABLE GAS DETECTOR
67816
Revision D
29
6. Operator Maintenance
6.1. Replacing/Recharging Batteries
The monitor’s handle contains three “C” size batteries (see Figure
30: GT-Fire Battery Location
).
for the allowed battery types.
Figure 30: GT-Fire Battery Location
6.1.1. Replacing Batteries
WARNING: BATTERIES MUST BE CHANGED ONLY IN A LOCATION
KNOWN TO BE NON-HAZARDOUS.
WARNING: DO NOT MIX NEW BATTERIES WITH USED BATTERIES OR
MIX BATTERIES FROM DIFFERENT MANUFACTURERS.
WARNING: DO NOT MIX ALKALINE AND RECHARGEABLE BATTERIES.
WARNING: TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE
ATMOSPHERES, ALWAYS REMOVE BATTERIES BEFORE SERVICING THE
MONITOR.
WARNING: TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE
ATMOSPHERES, READ, UNDERSTAND AND ADHERE TO THE
MANUFACTURER’S MAINTENANCE PROCEDURES.