U
SER
M
ANUAL
8
K
/4
K
CL
M
ONO
–
R
EV
I
–
06/2017
P
A G E
|
49
Save & Restore LUT in User Banks
: The LUT loaded in RAM memory can be saved or restored in/from
4 User banks.
These functions are available in the LUT/Save & Restore LUT Settings section :
o
Restore LUT from Bank
(
RestoreLUTFromBank
) : Restore the LUT from a User Bank in the current
RAM Memory.
Read function : “
r rlut
” : Get the current LUT Bank used
Returned by the camera : 1 to 4 for User banks
Write function : “
w rlut <val>
” : Bank <val> 1 to 4 for User banks
o
Save LUT in User Bank
(
SaveLUTToBank
) : Save current LUT in User Bank
Can not de read
Write function : “
w slut
<val>
” : User bank <val> if from 1 to 4.
The bank number <val> is given in (
LUTSetSelector
)
LUT User Bank Usage
At the power up :
- Last User Bank used is loaded in RAM
7.6.1
Command Tables
Feature
Commands
Description
LUTEnable
r lute
Get LUT status
w lute 0
Disable LUT (“False”)
w lute 1
Enable LUT (“True”)
No direct feature
r lutc <addr>
Read 128 LUT coefficients starting from address <addr> from 0 to
4095-128. Return value is in hexadecimal, without space between
values. (one unsigned char per coef)
w lutc <addr>
<val>
Write 128 LUT coefficients starting from address <addr> from 0 to
4095-128. <val> is the concatenation of individual LUTvalue,
without space between values.
Feature
Commands
Description
RestoreLUTFromBank
r rlut
Get the current LUT bank (saved or restore)
w rlut <val>
Restore current LUT from LUT bank number <val>, from 1 to 4;
<val> comes from LUTSetSelector.
SaveLUTToBank
w slut <val>
Save current LUT to LUT FFC bank number <val>, from 1 to 4;
<val> comes from LUTSetSelector.
User1
User2
User3
User4
User banks
Ram Memory
Save
Load
Upload/load from/to a Txt file