Saving and Restoring Camera Settings
The p aram eters u sed to select, load and save u ser sets are grou p ed together u nd er the Cam era
Inform ation set of featu res. There are 8 u ser sets available and one factory set.
Camera Information
Parameter
Choices
User Set Defau lt Selector
Select the cam era p aram eters to load w hen the cam era is reset or p ow ered u p as the
Factory set, or as User Set 1 to 8.
Selecting the set from the list au tom atically saves it as the d efau lt set.
User Set Selector
Select the Factory or User set to Save or Load .
-Factory Set
-User Set 1 to 8.
User Set Load
Load the set sp ecified by User Set Selector to the cam era and m ake it the active /
cu rrent set.
User Set Save
Save the cu rrent set as selected u ser set.
Description of the Camera Settings
The cam era op erates in one of three settings:
1.
Cu rrent session.
2.
User setting.
3.
Factory setting (read -only).
4.
Defau lt setting.
The cu rrent settings can be saved (thereby becom ing the u ser setting) u sing the User Set Save p aram eter.
A p reviou sly saved u ser setting (User Set 1 to 8) or the factory settings can be restored u sing the User Set
Selector and User Set Load p aram eters.
Either the Factory or one of the User setting s can be saved as the Defau lt Setting by selecting the set in the
User Set Defau lt Selector. The chosen set au tom atically saves as the d efau lt setting and is the set load ed
w hen the cam era is reset or p ow ered u p .