2150EX Area Velocity Flow Module
Section 2 Preparation and Installation
2-8
WARNING
The sensor mounting ring is a potential isolated charge
carrier. Your installation MUST satisfy earthing
requirements. Refer to IEC 60079-14 section 12.2.4 and IEC
60079-11.
2.4 Portable Installations
For portable installations, the 2150EX module is stacked with a
2191EX or 2196EX battery module. It communicates with a com-
puter or 2100 Series network device via an EX Network Cable
(for potentially explosive atmospheres) and an EX Isolator Cable.
The 2191EX module contains two sealed, replaceable battery
packs for use in gas hazard zones 0, 1, and 2.
The 2196EX is a rechargeable module for use in gas hazard zones
1 and 2. For detailed information about the 2196EX, turn to
section 2.4.6.
2.4.1 Installation Example
The following steps may be used as a guide to install a basic, por-
table 2150EX system, including the 2150EX module, the 2191EX
battery module, and an AV2150EX sensor.
1. Prepare the Battery Module.
a. Install the battery packs (See section 2.4.2).
b. Inspect the desiccant (2.4.3).
2. Inspect 2150EX module desiccant (2.4.4).
3. Assemble the system.
a. Install the 2150EX module (2.4.5 and Figure 2-6).
b. Attach the AV2150EX sensor cable to the 2150EX mod-
ule (2.7).
4. Install the AV2150EX sensor in the flow stream (2.7.1).
5. Connect the interrogation cable and connect to the site
with
Flowlink
software (2.6).
a. Create the site by Quick Connecting to the modules.
b. Set up the site and module settings.
6. Disconnect from the site and replace all protective caps.
2.4.2 Install Battery Module
Batteries
The 2191EX Battery Module requires two LTC2191EX 8 volt
lithium battery packs (P/N 68-2000-022) or two SLA2191EX 8
volt lead-acid battery packs (P/N 68-2000-023). These packs are
sealed and explosion protected, so they can be safely installed in
a potentially explosive atmosphere.
WARNING
Substitution of components will impair intrinsic safety.
Summary of Contents for 2150EX
Page 2: ......
Page 4: ......
Page 26: ...2150EX Area Velocity Flow Module Section 1 Introduction 1 12 ...
Page 78: ...2150EX Area Velocity Flow Module Section 4 Modbus Protocol 4 10 ...
Page 90: ...2150EX Area Velocity Flow Module Section 5 Maintenance 5 12 ...
Page 92: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 2 ...
Page 93: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 3 ...
Page 94: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 4 ...
Page 95: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 5 ...
Page 96: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 6 ...
Page 98: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 8 602002331 A ...
Page 99: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 9 ...
Page 100: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 10 ...
Page 101: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 11 ...
Page 102: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 12 ...
Page 103: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 13 ...
Page 104: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 14 ...
Page 105: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 15 ...
Page 106: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 16 ...
Page 107: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 17 ...
Page 108: ...2150EX Area Velocity Flow Module Appendix A Replacement Parts A 18 ...
Page 134: ...Compliance Statements ...
Page 136: ......
Page 138: ......
Page 140: ......
Page 142: ......
Page 144: ...arranty ...
Page 146: ......